4.3 Article

First visualisation of bacterial biofilms in 3D porous media with neutron microtomography without contrast agent

期刊

JOURNAL OF MICROSCOPY
卷 285, 期 1, 页码 20-28

出版社

WILEY
DOI: 10.1111/jmi.13063

关键词

Neutron tomography; X-ray tomography; biofilm; 3D porous media

资金

  1. Universite Grenoble Alpes through the IRS Project 'Neutron tomography as a novel tool for imaging bacterial biofilms inside 3D porous media'
  2. ILL. 3SR is part of LabEx Tec [21 -ANR11-LABX-0030]
  3. Institut Carnot PolyNat [ANR16CARN-0025]
  4. 'COGITO' Hubert-Curien Partnership (Campus France) [42815QE]

向作者/读者索取更多资源

Characterizing bacterial biofilm growth in porous media is essential for biofouling research, and X-ray microtomography has been a useful tool. However, concerns over contrast agent use have led researchers to explore neutron tomography as an alternative imaging method. Results showed that neutron tomography provided consistent biofilm distribution observations with X-ray microtomography, but the images were too noisy for quantitative measurements.
Characterising bacterial biofilm growth in porous media is important for developing reliable numerical models of biofouling in industrial biofilters. One of the promising imaging methods to do that has been a recent successful application of X-ray microtomography. However, this technique requires a contrast agent (1-chloronaphtalene, for example) to distinguish biofilm from the liquid phase, which raises concern about biofilm disruption and impaired image interpretation. To overcome these drawbacks, we tested a new approach based on neutron tomography (NT), which does not need a contrast agent, by imaging two types of porous media (polytetrafluoroethylene - PTFE - and clay beads of various diameters) in glass or PTFE tubes in which bacterial biofilms were grown for 7 days and by comparing these images with the ones obtained with X-ray microtomography. NT images showed that the biofilm formed preferentially around the beads and at bead/bead interface. Visual comparison of both imaging techniques showed consistent biofilm spatial distributions and that the contrasting agent did not significantly disrupt the biofilm. NT images, on the other hand, were still too noisy to allow quantitative measurements. Therefore, X-ray microtomography (provided it uses non-disruptive contrast agents) seems to provide more reliable microstructural descriptors.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据