4.6 Article

Influence of expiratory flow pulsatility on the effectiveness of a surgical mask

出版社

SPRINGERNATURE
DOI: 10.1038/s41370-022-00416-x

关键词

COVID-19; Face masks; Coughing dynamics

资金

  1. National Science Foundation [2035488, 2035489]
  2. Directorate For Engineering
  3. Div Of Chem, Bioeng, Env, & Transp Sys [2035489] Funding Source: National Science Foundation
  4. Div Of Chem, Bioeng, Env, & Transp Sys
  5. Directorate For Engineering [2035488] Funding Source: National Science Foundation

向作者/读者索取更多资源

This study aims to assess the influence of expiratory flow pulsatility on the effectiveness of a surgical face mask by quantifying and classifying the flow leakage around the mask. The results show that multi-pulsed expiratory flow events generate greater leakage flow around the mask than single-pulsed events.
Background Expiratory events, such as coughs, are often pulsatile in nature and result in vortical flow structures that transport expiratory particles. The World Health Organization recommends wearing face masks to reduce the airborne transmission of diseases such as SARS-CoV-2 (COVID-19). However, masks are not perfect as flow leakage occurs around the mask, and their effectiveness under realistic (multi-pulse) coughing conditions is unknown. Objective To assess the influence of expiratory flow pulsatility on the effectiveness of a surgical face mask by quantifying and classifying the flow leakage around the mask. Methods A custom-built pulsatile expiratory flow simulator is used to generate single- and multi-pulsed coughing events. Flow visualization and particle image velocimetry are used to assess the penetration distance and volume of leakage flow at the top and sides of a surgical mask. Results Leakage flow velocity profiles at the top and sides of a surgical mask take the form of a wall jet and a free-shear jet, respectively. Multi-pulsed expiratory flow events are found to generate greater leakage flow around the mask than single-pulsed events. Significance For the first time, the leakage volume of a surgical mask is shown to be correlated to the pulsatile nature of a cough. Impact statement The novelties of this study are: First, flow field measurements are used to quantify and classify the leakage flow fields around the top and sides of a surgical mask, providing a benchmark for quantitative modeling of leakage flow velocity profiles. Second, the influence of pulsatility on the effectiveness of surgical face masks is studied by quantifying the leakage volume. For the first time, the leakage volume of a surgical mask is shown to be correlated to the pulsatile nature of a cough, as multi-pulsed expiratory flow events are found to generate greater flow leakage around the mask than single-pulsed events.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据