4.4 Article

Not Every Low-Dose Is Low-Dose: Impact of Revising Low-Dose CT Protocol on Mean Effective Radiation Exposure

期刊

JOURNAL OF ENDOUROLOGY
卷 36, 期 6, 页码 835-840

出版社

MARY ANN LIEBERT, INC
DOI: 10.1089/end.2021.0659

关键词

computed tomography; low-dose; urolithiasis; effective radiation

资金

  1. Endourological Society Student Summer Scholarship

向作者/读者索取更多资源

The study found that urologists primarily ordered low-dose CT scans in both phases, and after the LD CT scan protocol was revised in March 2019, there was a significant decrease in mean effective radiation exposure per LD CT. In addition, there were significant differences in mean ERE from LD CT scans between two hospitals in the same health system.
Introduction: According to the American Urological Association imaging guidelines, patients presenting with renal colic should undergo low-dose (LD) rather than standard-dose (SD) noncontrast CT. The aim of the present study was to assess how often physicians ordered LD CT scans and to calculate mean effective radiation exposure (ERE) from CT scans from dose length products, and determine mean cumulative ERE over 1-year follow-up period.Methods: After obtaining ethics approval, a retrospective chart review was conducted for patients with renal colic presenting to the emergency department between August 1, 2015 and July 31, 2016 (Phase I) and between April 1, 2019 and October 1, 2019 (Phase II). All imaging studies performed within 1-year of initial presentation were cataloged.Results: In Phase I, 146 patients, with mean age of 51 years and mean body mass index (BMI) of 28.6 kg/m(2), underwent 220 CT scans. In Phase II, 225 patients, with mean age of 55 years and mean BMI of 26.7 kg/m(2), underwent 273 CT scans. Urologists were the only physicians ordering LD CT scans and they ordered significantly more LD than SD CT scans (71.3% vs 28.7%, p < 0.001). In Phase II, after revision of LD CT scan protocol in March 2019, the mean ERE per LD CT significantly decreased (6.5 vs 1.6 mSv, p < 0.001). In addition, there were significant differences in mean ERE from LD CT scans between two hospitals in the same health system (1.6 vs 7.8 mSv, p < 0.001). The mean cumulative ERE in Phase II over the 1-year period was 19.3 mSv, with 6.9% of patients exceeding 50 mSv.Conclusions: Although LD CT scans are being ordered, a small percentage of patients continue to exceed the 50 mSv annual threshold. It is important to keep track of mean ERE of LD CT scans and collaborate with medical physicists and the diagnostic imaging department to further refine LD CT scan protocols since not every low-dose is low-dose.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据