4.6 Article

Fast and Robust Exudate Detection in Retinal Fundus Images Using Extreme Learning Machine Autoencoders and Modified KAZE Features

期刊

JOURNAL OF DIGITAL IMAGING
卷 35, 期 3, 页码 496-513

出版社

SPRINGER
DOI: 10.1007/s10278-022-00587-x

关键词

Autoencoders; Diabetic Retinopathy; Exudates; KAZE Features; Retina

向作者/读者索取更多资源

Diabetic retinopathy is a common and serious health condition that affects the retinal blood vessels and can lead to vision loss. In this paper, a novel method based on modified KAZE features and ELMAE is proposed to accurately localize exudates in fundus images. The experimental results show that the proposed method achieves high sensitivity, specificity, and accuracy, with a short processing time.
Diabetic retinopathy(DR) is a health condition that affects the retinal blood vessels(BV) and arises in over half of people living with diabetes. Exudates(EX) are significant indications of DR. Early detection and treatment can prevent vision loss in many cases. EX detection is a challenging problem for ophthalmologists due to its different sizes and elevations as retinal fundus images frequently have irregular illumination and are poorly contrasting. Manual detection of EX is a time-consuming process to diagnose a mass number of diabetic patients. In the domain of signal processing, both SIFT (scale-invariant feature transform) and SURF (speed-up robust feature) methods are predominant in scale-invariant location retrieval and have shown a range of advantages. But, when extended to medical images with corresponding weak contrast between reference features and neighboring areas, these methods cannot differentiate significant features. Considering these, in this paper, a novel method is proposed based on modified KAZE features, which is an emerging technique to extract feature points and extreme learning machine autoencoders(ELMAE) for robust and fast localization of the EX in fundus images. The main stages of the proposed method are pre-processing, OD localization, dimensionality reduction using ELMAE, and EX localization. The proposed method is evaluated based on the freely accessible retinal database DIARETDB0, DIARETDB1, e-Ophtha, MESSIDOR, and local retinal database collected from Silchar Medical College and Hospital(SMCH). The sensitivity, specificity, and accuracy obtained by the proposed method are 96.5%, 96.4%, and 97%, respectively, with the processing time of 3.19 seconds per image. The results of this study are satisfactory with state-of-the-art methods. The results indicate that the approach taken can detect EX with less processing time and accurately from the fundus images.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据