4.5 Article

Structural performance of cold-formed steel built-up section beams under non-uniform bending

期刊

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jcsr.2021.107050

关键词

Built-up sections; Critical elastic buckling strengths; Direct strength method; Four-point bending tests; Numerical modelling; Strength predictions

向作者/读者索取更多资源

This paper presents experimental investigation and numerical analyses on cold-formed steel built-up open and closed section beams under either uniform or non-uniform minor axis bending. The study explores the effect of non-uniform bending on the behaviour of these flexural members. Experimental tests and finite element simulations were conducted to examine the flexural performance of the built-up section members. The results were used to evaluate the appropriateness of the current design rules and recommend modified rules for the design of cold-formed steel built-up section beams.
The experimental investigation and numerical analyses are presented in this paper on cold-formed steel built-up open and closed section beams under either uniform or non-uniform minor axis bending. To the best knowledge of the authors, this is the first study devoted to exploring the effect of non-uniform bending on the behaviour of cold-formed steel built-up section flexural members. In the experimental investigation, the built-up section specimens were assembled by fastening two individual channels as press-braked from G500 and G550 steel sheets. Four-point bending tests of eighteen specimens with varying moment distributions were conducted to examine the flexural performance of the built-up section members experiencing uniform bending and moment gradients. In the numerical simulation, the finite element models were established for the built-up section flexural members and calibrated against the experimental results in terms of moment-deflection response, failure mode and moment capacity. Based on the validated finite element models, additional 300 numerical data of the built-up section beams under uniform and non-uniform minor axis bending were generated through a parametric study. Subsequently, the comparison of moment capacities obtained from the 18 tests and 300 numerical predictions with nominal strengths was carried out to evaluate the appropriateness of the current direct strength method as prescribed in the North American Specification for the built-up section flexural members. Aimed to achieve more suitable strength predictions, the modified design rules were recommended in this study and proven to be generally reliable as well as accurate for the design of cold-formed steel built-up section beams.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据