Seismic Behavior of Repaired and Externally FRP-Jacketed Short Columns Built with Extremely Low-Strength Concrete

期刊

出版社

ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/(ASCE)CC.1943-5614.0001179

关键词

Carbon; Fiber-reinforced polymer (FRP); Glass; Predamage; Reinforced concrete; Shear; Short columns; Strengthening

资金

  1. TUBITAK (The Scientific and Technological Research Council of Turkey)

向作者/读者索取更多资源

This study investigates the seismic response of FRP-retrofitted low-strength RC short columns and analyzes the effects of extremely low-strength concrete and different levels of predamage on the behavior of FRP-retrofitted substandard short columns. The research includes experimental and analytical phases, with test results providing important knowledge about the seismic behavior and repair options for such columns. The performance of relevant design documents in predicting the shear strength of FRP-retrofitted columns was also tested through comparison with experimental results.
Short columns with deficiencies of low-strength concrete and large spacing of transverse reinforcement are quite common in construction practice in many developing countries in seismically active regions. Therefore, it is important to retrofit this type of column to avoid negative consequences in the case of severe damage. External fiber-reinforced polymer (FRP) jacketing is one of the most practical methods to retrofit reinforced concrete (RC) frame members against shear actions. However, knowledge of the seismic behavior of FRP-retrofitted RC short columns is still limited. Thus, the aim of this study was to investigate the seismic response of FRP-retrofitted low-strength RC short columns with and without predamage through the testing of 11 short column specimens representing old and deficient RC buildings. Accordingly, the results of a research program on the seismic behavior of such columns and on their repair and FRP retrofitting, covering experimental and analytical phases, are presented. In the experimental phase, test results obtained for short columns, FRP-retrofitted short columns, and repaired and retrofitted short columns are documented. Test results provide important knowledge about the effects of extremely low-strength concrete, and of different levels of predamage on the behavior of FRP-retrofitted substandard short columns. In the analytical phase, the performance of relevant design documents in predicting the shear strength of such columns retrofitted with FRP jacketing was tested through the comparison of predicted and experimental results.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据