4.6 Article

Stress-Strain Behavior of FRP-Confined Recycled Aggregate Concrete in Square Columns of Different Sizes

期刊

出版社

ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/(ASCE)CC.1943-5614.0001150

关键词

Recycled aggregate concrete (RAC); Fiber-reinforced polymer (FRP); Stress-strain behavior; Size effect; Confinement; Square columns

资金

  1. National Natural Science Foundation of China [51678161, 51978281, 52008361]
  2. Guangdong Provincial Key Laboratory of Modern Civil Engineering Technology [2021B1212040003]

向作者/读者索取更多资源

The study investigated the size effect of square recycled aggregate concrete columns confined by glass fiber reinforced polymer, showing that the size effect indeed existed and was amplified by the presence of recycled aggregate.
The application of recycled aggregate concrete (RAC) has so far mainly been limited to nonstructural components because of its inferior short- and long-term performance compared with normal concrete. Encasement of RAC with a fiber-reinforced polymer (FRP) tube has been demonstrated to be an effective technique to improve both the mechanical properties and durability of RAC. A number of studies have been carried out on FRP-confined RAC in circular columns. However, only a limited number of studies have examined the behavior of FRP-confined RAC in rectangular columns, and the existing test specimens were all small-scale. Existing studies have shown that there may exist a significant behavioral difference between small- and large-scale FRP-confined rectangular concrete columns (i.e., column size effect). Against this background, a first-ever experimental study on glass FRP (GFRP)-confined square RAC columns of three different sectional widths ranging from 200 to 400 mm was conducted and the results are presented in this paper. The same FRP confinement stiffness was adopted for the columns of different sizes so that the possible column size effect could be examined. The test results showed that the size effect indeed existed in the test FRP-confined square RAC columns and the presence of recycled aggregate amplified such effect. The size effect should be considered in the design of such columns especially when the coarse aggregate replacement ratio is relatively large. The accuracies of three existing strength models for FRP-confined normal concrete in square columns were also evaluated using the test results.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据