Poly (4,4'-diamino-p-terphenyl-triazine) (PDT) coated stir bar showed superior extraction performance and faster kinetics for target phthalate esters compared to commercial polydimethylsiloxane coated stir bar. Combined with HPLC-DAD, the method achieved low detection limits and high enrichment factors for trace analysis of PAEs plasticizers. The potential of the method was demonstrated by detecting target PAEs in Chinese liquor and mineral water samples with good recoveries.
Cyanuric chloride and 4,4'-diamino-p-terphenyl were adopted as monomers to synthesize poly (4,4'-diamino-p-terphenyl-triazine) (PDT) covalent organic polymer. PDT coated stir bar was prepared and evaluated for the extraction of five phthalate esters (PAEs) with relatively lower logP values (2.7-4.9), including diethyl phthalate, diallyl phthalate, dipropyl phthalate, benzylbutyl phthalate and dibutyl phthalate. It exhibited higher extraction recovery (> 65%) and faster extraction kinetics (50 min vs 240 min) for target PAEs over commercial polydimethylsiloxane coated stir bar. Based on the superior performance, PDT coated stir bar sorptive extraction was combined with high-performance liquid chromatography-diode array detection for trace analysis of five PAEs plasticizers. The limits of detection for target PAEs were 0.04-0.27 mu g/L, with the enrichment factors of 54-80-fold. The potential of the method was demonstrated by detecting five target PAEs in Chinese liquor and mineral water samples. No target analytes were detected in Chinese liquor sample, and recoveries of 85.4-109% were obtained for target analytes in spiked liquor samples; trace diethyl phthalate (1.19-2.98 mu g/L) and dibutyl phthalate (0.77-0.91 mu g/L) were detected in two mineral water samples, with recoveries of 85.4-117% and 87.4-117% respectively in spiked mineral water samples. (C) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据