4.4 Article

MUM-1 immunohistochemistry has high accuracy and reliability in the diagnosis of chronic endometritis: a multi-centre comparative study with CD-138 immunostaining

期刊

出版社

SPRINGER/PLENUM PUBLISHERS
DOI: 10.1007/s10815-021-02356-1

关键词

Chronic endometritis; MUM-1; CD138; Diagnostic accuracy; Plasma cells

向作者/读者索取更多资源

The study indicates that IHC for MUM-1 and CD-138 have similar accuracy in detecting endometrial stromal plasma cells. However, MUM-1 shows higher reliability in the paired comparison of individual samples. Therefore, MUM-1 may be a novel and promising add-on technique for CE diagnosis.
Purpose The current gold standard for chronic endometritis (CE) diagnosis is immunohistochemistry (IHC) for CD-138. However, IHC for CD-138 is not exempt from diagnostic limitations. The aim of our study was to evaluate the reliability and accuracy of MUM-1 IHC, as compared with CD-138. Methods This is a multi-centre, retrospective, observational study, which included three tertiary hysteroscopic centres in university teaching hospitals. One hundred ninety-three consecutive women of reproductive age were referred to our hysteroscopy services due to infertility, recurrent miscarriage, abnormal uterine bleeding, endometrial polyps or myomas. All women underwent hysteroscopy plus endometrial biopsy. Endometrial samples were analysed through histology, CD138 and MUM-1 IHC. The primary outcome was to evaluate the diagnostic accuracy of MUM-1 IHC for CE, as compared with CD-138 IHC. Results Sensitivity and specificity of CD-138 and MUM-1 IHC were respectively 89.13%, 79.59% versus 93.48% and 85.03%. The overall diagnostic accuracy of MUM-1 and CD-138 IHC were similar (AUC = 0.893 vs AUC = 0.844). The intercorrelation coefficient for single measurements was high between the two techniques (ICC = 0.831, 0.761-0.881 95%CI). However, among CE positive women, MUM-1 allowed the identification of higher number of plasma cells/hpf than CD-138 (6.50 [SD 4.80] vs 5.05 [SD 3.37]; p = 0.017). Additionally, MUM-1 showed a higher inter-observer agreement as compared to CD-138. Conclusion IHC for MUM-1 and CD-138 showed a similar accuracy for detecting endometrial stromal plasma cells. Notably, MUM-1 showed higher reliability in the paired comparison of the individual samples than CD-138. Thus, MUM-1 may represent a novel, promising add-on technique for the diagnosis of CE.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据