Individualized Scan Protocols in Abdominal Computed Tomography Radiation Versus Contrast Media Dose Optimization

期刊

INVESTIGATIVE RADIOLOGY
卷 57, 期 6, 页码 353-358

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/RLI.0000000000000844

关键词

computed tomography; abdomen; liver; contrast media; radiation dose; renal insufficiency; age; image quality; automated tube voltage selection

向作者/读者索取更多资源

This study aimed to evaluate the feasibility of optimizing radiation or contrast media dose in abdominal imaging compared with a combined approach. The results showed that personalized adjustment of radiation or contrast media dose can reduce radiation exposure or contrast media usage without compromising image quality.
Background In contrast-enhanced abdominal computed tomography (CT), radiation and contrast media (CM) injection protocols are closely linked to each other, and therefore a combination is the basis for achieving optimal image quality. However, most studies focus on optimizing one or the other parameter separately. Purpose Reducing radiation dose may be most important for a young patient or a population in need of repetitive scanning, whereas CM reduction might be key in a population with insufficient renal function. The recently introduced technical solution, in the form of an automated tube voltage selection (ATVS) slider, might be helpful in this respect. The aim of the current study was to systematically evaluate feasibility of optimizing either radiation or CM dose in abdominal imaging compared with a combined approach. Methods Six Gottingen minipigs (mean weight, 38.9 +/- 4.8 kg) were scanned on a third-generation dual-source CT. Automated tube voltage selection and automated tube current modulation techniques were used, with quality reference values of 120 kV(ref) and 210 mAs(ref). Automated tube voltage selection was set at 90 kV semimode. Three different abdominal scan and CM protocols were compared intraindividually: (1) the standard combined protocol, with the ATVS slider position set at 7 and a body weight-adapted CM injection protocol of 350 mg I/kg body weight, iodine delivery rate (IDR) of 1.1 g I/s; (2) the CM dose-saving protocol, with the ATVS slider set at 3 and CM dose lowered to 294 mg I/kg, resulting in a lower IDR of 0.9 g I/s; (3) the radiation dose-saving protocol, with the ATVS slider position set at 11 and a CM dose of 441 mg I/kg and an IDR 1.3 g I/s, respectively. Scans were performed with each protocol in arterial, portal venous, and delayed phase. Objective image quality was evaluated by measuring the attenuation in Hounsfield units, signal-to-noise ratio, and contrast-to-noise ratio of the liver parenchyma. The overall image quality, contrast quality, noise, and lesion detection capability were rated on a 5-point Likert scale (1 = excellent, 5 = very poor). Protocols were compared for objective image quality parameters using 1-way analysis of variance and for subjective image quality parameters using Friedman test. Results The mean radiation doses were 5.2 +/- 1.7 mGy for the standard protocol, 7.1 +/- 2.0 mGy for the CM dose-saving protocol, and 3.8 +/- 0.4 mGy for the radiation dose-saving protocol. The mean total iodine load in these groups was 13.7 +/- 1.7, 11.4 +/- 1.4, and 17.2 +/- 2.1 g, respectively. No significant differences in subjective overall image or contrast quality were found. Signal-to-noise ratio and contrast-to-noise ratio were not significantly different between protocols in any scan phase. Significantly more noise was seen when using the radiation dose-saving protocol (P < 0.01). In portal venous and delayed phases, the mean attenuation of the liver parenchyma significantly differed between protocols (P < 0.001). Lesion detection was significantly better in portal venous phase using the CM dose-saving protocol compared with the radiation dose-saving protocol (P = 0.037). Conclusions In this experimental setup, optimizing either radiation (-26%) or CM dose (-16%) is feasible in abdominal CT imaging. Individualizing either radiation or CM dose leads to comparable objective and subjective image quality. Personalized abdominal CT examination protocols can thus be tailored to individual risk assessment and might offer additional degrees of freedom.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据