This research experimentally investigated the effects of hyper and microgravity on a vapor compression cycle during parabolic flights. The results showed that the cycle operation was mildly affected by the varying g-forces, and most measurements and performance indicators remained within normal range. A loss of superheat was observed in one set of parabolas due to gravity changes, but other sets maintained normal operation of superheat and subcooling.
Long duration manned space travel is projected to bring a need for large cooling capacities in microgravity for typical freezing and refrigeration temperatures. Among possible cooling technology alternatives, the vapor compression cycle has the highest coefficient of performance but the confidence for microgravity applications is very low. This research effort experimentally investigated the effects of hyper and microgravity on a vapor compression cycle during parabolic flights. A total of 122 parabolas were flown over four days with a repeating pattern of 5 sequential parabolas. Transient data of the evaporation temperature and cooling capacity for selected parabolas are presented as the test stand experienced alternating hyper and microgravity levels. Most measurements and performance indicators showed mild effects on the cycle operation during the varying g-forces. For example, the refrigerant side cooling capacity fluctuated on average within a band of 15% (+/-7.5%) through all sets of parabolas. A loss of superheat due to gravity changes was observed for one set of parabolas but the set was started with an unusually low superheat of only 3 K. For all other sets of parabolas, superheat and subcooling were maintained. Flight results were compared with inclination testing in a laboratory using the same test stand. Inclination changes from-90? to + 90? impacted both the liquid and suction line mass flow rate while varying the gravity level between 0 and 1.8 g affected the suction line mass flow rate but not the liquid line mass flow rate.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据