4.5 Article

Experimental analysis of condensation of zeotropic mixtures from 70 °C to 90 °C in a plate heat exchanger

期刊

INTERNATIONAL JOURNAL OF REFRIGERATION
卷 137, 期 -, 页码 166-177

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.ijrefrig.2022.01.029

关键词

High temperature condensation; Zeotropic mixture; Temperature effects; Pressure drop correlation

向作者/读者索取更多资源

This study presents an experimental analysis of high temperature condensation of zeotropic mixtures in a plate heat exchanger. The results show that the R1234ze(E)/R1233zd(E) mixture has higher heat transfer coefficient and frictional pressure drop compared to the R134a/R245fa mixture. A modified model predicts the heat transfer data with good accuracy, and a new pressure drop correlation accurately predicts the pressure drop results.
High temperature condensation is relevant for the heat pump system used for the district heating and the organic Rankine cycle system used for combined heat and power generation. By using a zeotmpic mixture as working fluid in such systems, it is possible to achieve a higher system efficiency compared with those of pure fluids. Only two previous studies addressing zeotropic mixture high temperature condensation in plate heat exchangers are available in the open literature, and these studies considered ethanol/water mixtures. The current works present an experimental analysis of high temperature condensation of zeotropic mixtures in a plate heat exchanger. We analyzed the condensation of the hydrofluomolefin mixture R1234ze(E)/R1233zd(E) and the hydrofluomcarbon mixture R134a/R245fa with different mass compositions at various condensation temperatures and mass fluxes. Based on the experimental results, we analyzed the temperature effects on the condensation heat transfer and identified a convective-dominated condensation heat transfer process. Furthermore, the results suggest that the mixture R1234ze(E)/R1233zd(E) has the up to 8.5% and 4.4% higher heat transfer coefficient and frictional pressure drop, respectively, than the R134a/R245fa mixture. A modified Silver-Bell-Ghaly model predicted the heat transfer data with a 7.1% mean absolute percentage deviation between the predicted and experimental results, and a new pressure drop correlation developed using the mixture test data predicted the pressure drop results with a 6.2% mean absolute percentage deviation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据