4.7 Article

A data fusion approach with high spatiotemporal resolution for wall temperature measurement upon jet impingement

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2021.122084

关键词

Proper orthogonal decomposition (POD); Compressed sensing (CS); Jet impingement; Heat transfer; Temperature measurement

资金

  1. National Natural Science Foundation of China [91941101]

向作者/读者索取更多资源

A data fusion method combining POD and CS is proposed for high spatiotemporal resolution temperature measurement of rocket engine combustor chamber walls.
A high spatial and temporal resolution of wall temperature measurement is beneficial for liquid film cooling design for thermal protection of rocket engine combustor chamber. The conventional thermocouple method has a high sampling frequency up to 50 kHz, but it is based on point measurement. The infrared (IR) thermal technique can achieve a two-dimensional surface temperature measurement, but the current sampling frequency is limited to a few hundreds of Hz. Here we report the application of the data fusion approach, which is integrated with proper orthogonal decomposition (POD) and compressed sensing (CS) to reconstruct the temperature field of a wall with high spatiotemporal resolution. In this approach, the low-frequency IR thermal camera data was analyzed by POD to acquire the POD modes. The high-frequency thermocouple data with the POD modes were utilized to get the high-frequency mode coefficients by CS. Subsequently, the temperature information reconstruction was completed with POD modes and the mode coefficients. The data fusion method was applied to reconstruct the 250 x 400 pixels temperature field with a frequency of 100 Hz. Using 10 thermocouples and the IR camera with sampling frequency f = 2 Hz, the root mean square error (RMSE) of the reconstructed temperature field is 1.11%, which shows the reliability of the present approach. The less thermocouple and the lower IR camera sampling frequency leads to poorer reconstruction quality, though the effect of IR camera sampling frequency is less significant than the number of thermocouples. The optimized sensor number and sampling frequency were determined by the RMSE in this paper. The RMSE of the data fusion method with the initial temperature T-0 from 40 degrees C to 120 degrees C and the flow rate Q from 45 mL/min to 120 mL/min are less than 1.4%, which shows wide applicability of the present approach. (C) 2021 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据