4.5 Article

Modernized sensor measurement technique for determination of chlorine in bathing water Sensor for chlorine determination in bathing water

期刊

出版社

SPRINGER
DOI: 10.1007/s13762-022-03966-7

关键词

Colorimetric method; Indoor swimming pool; Monitoring; River water; Validation

资金

  1. Ministry of Education, Science and Technological Development [451-03-68/2020-14/200156]
  2. Interreg IPA CBC Croatia-Serbia Project [AF_HR-RS135_ SeNs_Wetlands]

向作者/读者索取更多资源

A colorimetric fiber optic sensor was developed for determination of total and residual chlorine in water. The sensor detects values in the red, green, blue color space and converts them into a user-oriented hue, saturation, value color model. The repeatability and effectiveness of the sensor method for chlorine measurement in water were validated by comparing the results with standard chemical laboratory analysis. The sensor method showed potential for replacing expensive laboratory equipment due to its efficiency, low cost, simplicity, small size, and repeatability.
Colorimetric fiber optic sensor was developed for determination of total and residual chlorine in water. Developed sensor is based on absorption and detects values in the red, green, blue color space which is converted in user-oriented hue, saturation, value color model. Hue, saturation, value color model is enforced to simplify determination of the key chemical parameters concentration in water. Concentrations of total and residual chlorine in swimming pool water samples were measured by standard chemical laboratory analysis and compared with concentrations obtained by sensor, to approve the repeatability and effectiveness of the innovative method for measurements in water. In addition, results obtained by analysis of surface water and swimming pool water were compared in order to prove effectiveness of sensor for different water media. The absolute value between the two compared methods for the total chlorine concentrations was in the range from 0.014 to 0.067 mg/L and for residual chlorine from 0.002 to 0.06 mg/L. The linearity of calibration curve, limit of detection and quantitation, accuracy and precision are investigated to prove the validation of the analytical procedure to determine chlorine species by sensor. Used sensor method with its advantages (efficiency, low cost, simple use, small size, repeatability) was used on laboratory scale for the first time separately for total chlorine and residual chlorine and demonstrates possibility to replace expensive standard analytical laboratory equipment.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据