4.3 Article

The role of three dimensional transesophageal echocardiography novel-score in the success of redo percutaneous balloon mitral valvuloplasty

期刊

出版社

SPRINGER
DOI: 10.1007/s10554-021-02452-4

关键词

Balloon mitral valvuloplasty; Transesophageal echocardiography; Wilkins score; Commissural fusion; Commissural calcification

向作者/读者索取更多资源

This study aimed to investigate the impact of WS and a novel 3D TEE score on the success of redo PBMV, finding a significant relationship between the novel 3D TEE score and procedural success, while no significant relationship was found with WS. The novel 3D TEE score may help in selecting suitable patients for successful redo PBMV, especially in those with high WS scores.
Mitral valve commissure evaluation is known to be important in the success of percutaneous balloon mitral valvuloplasty (PBMV) and Wilkins score (WS) is used in clinical practice. In our study, we aimed to determine whether WS in redo PBMV is sufficient in the success of procedure and additionally we have evaluated a novel scoring system including three dimensional (3D) transesophageal echocardiography (TEE) of the mitral valve structure before redo PBMV in terms of success of the procedure. Fifty patients who underwent redo PBMV were included in the study. The patients were divided into two groups according to the success of the Redo PBMV procedure which was defined as post-procedural MVA >= 1.5 cm(2) and post-procedural mitral regurgitation less than moderate by echocardiographic evaluation after PBMV. A novel score based on 3D TEE findings was created by analyzing the images recorded before Redo PBMV and by evaluating the mitral commissure and calcification. The role of traditional WS and novel score in the success of the procedure were investigated. In the study group, 36 patients (72%) had successful redo PBMV procedure. WS was 8 (IQR 7-9) and novel 3D TEE score was found 4 (IQR 3-4) in the whole study group. While no statistically significant relationship was found between WS and procedural success (p = 0.187), a statistically significant relationship was found between novel 3D TEE score and procedural success (p = 0.042). Specifically, the procedural successes rate was > 90% when novel 3D TEE score was < 4. The novel 3D TEE score might be an informative scoring system in the selection of suitable patients for successful redo PBMV, especially in patients who are considered for surgery due to the high WS.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据