4.7 Article

Improving the Robustness of Myoelectric Pattern Recognition for Upper Limb Prostheses by Covariate Shift Adaptation

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TNSRE.2015.2492619

关键词

Adaptation; classification; covariate shift; electromyogram (EMG); myoelectric signals; nonstationarities; pattern recognition

资金

  1. German Ministry for Education and Research (BMBF) via Bernstein Focus Neurotechnology (BFNT) Gottingen
  2. European Commission via Industrial Academia Partnerships and Pathways under Project AMYO [251555]
  3. Brain Korea 21 Plus Program

向作者/读者索取更多资源

Fundamental changes over time of surface EMG signal characteristics are a challenge for myocontrol algorithms controlling prosthetic devices. These changes are generally caused by electrode shifts after donning and doffing, sweating, additional weight or varying arm positions, which results in a change of the signal distribution-a scenario often referred to as covariate shift. A substantial decrease in classification accuracy due to these factors hinders the possibility to directly translate EMG signals into accurate myoelectric control patterns outside laboratory conditions. To overcome this limitation, we propose the use of supervised adaptation methods. The approach is based on adapting a trained classifier using a small calibration set only, which incorporates the relevant aspects of the nonstationarities, but requires only less than 1 min of data recording. The method was tested first through an offline analysis on signals acquired across 5 days from seven able-bodied individuals and four amputees. Moreover, we also conducted a three day online experiment on eight able-bodied individuals and one amputee, assessing user performance and user-ratings of the controllability. Across different testing days, both offline and online performance improved significantly when shrinking the training model parameters by a given estimator towards the calibration set parameters. In the offline data analysis, the classification accuracy remained above 92% over five days with the proposed approach, whereas it decreased to 75% without adaptation. Similarly, in the online study, with the proposed approach the performance increased by 25% compared to a test without adaptation. These results indicate that the proposed methodology can contribute to improve robustness of myoelectric pattern recognition methods in daily life applications.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据