4.6 Article

Spatiotemporal Flexible Sparse Reconstruction for Rapid Dynamic Contrast-Enhanced MRI

期刊

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
卷 69, 期 1, 页码 229-243

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBME.2021.3091881

关键词

Image reconstruction; Analytical models; Pipelines; Magnetic resonance imaging; Hospitals; Spatial resolution; Sparse matrices; DCE-MRI; parallel imaging; golden-angle radial sampling; sparse reconstruction; fast algorithm

资金

  1. National Key R&D Program of China [2017YFC0108703]
  2. National Natural Science Foundation of China [61971361, 61871341, 61671399, 61811530021]
  3. Natural Science Foundation of Fujian Province of China [2018J06018]
  4. Fundamental Research Funds for the Central Universities [20720180056]
  5. Science and Technology Program of Xiamen [3502Z20183053]
  6. Xiamen University Nanqiang Outstanding Talents Program

向作者/读者索取更多资源

In this paper, a new parallel CS reconstruction model for DCE-MRI is proposed to improve reconstruction quality by adjusting the importance of time and space sparsity. The results demonstrate that the proposed method achieves the lowest reconstruction error and highest image structural similarity at high acceleration rates.
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a tissue perfusion imaging technique. Some versatile free-breathing DCE-MRI techniques combining compressed sensing (CS) and parallel imaging with golden-angle radial sampling have been developed to improve motion robustness with high spatial and temporal resolution. These methods have demonstrated good diagnostic performance in clinical setting, but the reconstruction quality will degrade at high acceleration rates and overall reconstruction time remains long. In this paper, we proposed a new parallel CS reconstruction model for DCE-MRI that enforces flexible weighted sparse constraint along both spatial and temporal dimensions. Weights were introduced to flexibly adjust the importance of time and space sparsity, and we derived a fast-thresholding algorithm which was proven to be simple and efficient for solving the proposed reconstruction model. Results on both the brain tumor DCE and liver DCE show that, at relatively high acceleration factor of fast sampling, lowest reconstruction error and highest image structural similarity are obtained by the proposed method. Besides, the proposed method achieves faster reconstruction for liver datasets and better physiological measures are also obtained on tumor images.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据