4.7 Article

Optimisation of an Electrical Impedance Sensor for Use in Microfluidic Chip Electrophoresis

期刊

IEEE SENSORS JOURNAL
卷 22, 期 1, 页码 16-24

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2021.3127320

关键词

Tetrapolar; impedance; sensitivity; microfluidics; electrophoresis; cell constant; conductivity detection

资金

  1. Genetic Microdevices Ltd.

向作者/读者索取更多资源

This paper presents a novel approach to optimize the performance of tetrapolar electrical impedance measurement (TEIM) sensors in microfluidic chip electrophoresis (ME) applications. The study reveals the relationship between sensor, channel and sample parameters, and demonstrates that the sensor performance can be improved through appropriate design.
Label-free measurements using impedance sensing could enable microfluidic chip electrophoresis (ME) to be used in point-of-care (POC) diagnostics. However, impedance sensing methods reported in this field need considerable optimisation. GOAL: Develop a novel design process for optimising tetrapolar electrical impedance measurement (TEIM) sensor performance in ME applications through a systematic investigation a) of the impact of a TEIM sensor's design parameters on its performance in ME and b) of the relationship between the above parameters with those of the microfluidic channel and the sample to be sensed. METHODS: 3D FEM sensitivity simulations, verified experimentally, were carried out to study the impact of sensor and channel parameters on the measured impedance and their interrelationship. Subsequently, the impact of sensor parameters on sensing a sample band's conductivity and size was investigated. RESULTS: The impact of channel dimensions on transfer impedance measurements is significant. The non-linearity reported for transfer impedance measurement of volume conductors can be manipulated by appropriate sensor parameter design. The sensor performance can be optimised by designing electrode length and measurement electrode distance in relation to the channel height and sample band length, respectively. The sensor performance is not affected by the injection electrode distance. CONCLUSION: There is a relationship between sensor, channel and band parameters and this warrants establishing a systematic design process of TEIM sensors in ME. SIGNIFICANCE: This paper presents a novel approach to optimising the design of TEIM sensors in ME potentially providing significant performance improvements and thus allowing for label-free POC electrophoresis diagnostics.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据