4.7 Article

Knee Joint Curvature Detection System Based on Fiber Optic Mach-Zendler Interferometric Curvature Sensor

期刊

IEEE SENSORS JOURNAL
卷 21, 期 24, 页码 28017-28024

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2021.3121430

关键词

Human motion and posture; knee joint bending; fiber optic sensors; Mach-Zehnder interferometer; bending sensitivities

资金

  1. National Natural Science Foundation of China [61903280]
  2. Research on Motion Pattern Recognition of Exoskeleton Robot based on Curve Similarity Model [62106178]
  3. 3551 Optics Valley Talent Schema

向作者/读者索取更多资源

This paper presents a knee directional bending measurement device (KDBMD) using a Mach-Zehnder interferometer-based sensor, which has a wide measurement range and high sensitivity. Compared with an inclinometer, the proposed device shows excellent performance in both accuracy and responsiveness.
In the monitoring process of human motion and posture, the movement information of the knee joint is useful for diagnosis and rehabilitation evaluation. This paper presents a knee directional bending measurement device (KDBMD) using a Mach-Zehnder interferometer-based directional curvature (MZI-BDC) sensor that was fabricated by fusion-splicing a section of three-core fiber between two single-mode fibers with a core offset. Knee flexion and extension induce bending of the MZI-BDC sensor, changing its modal interference, which makes the sensor suitable for monitoring knee directional bending. Frequency-based modulation and swept source-based techniques are used in the KDBMD. The measurement range of the KDBMD is 0 degrees-90 degrees in both the forward and backward bending directions. For forward bending (bending direction of 0), the sensitivity and resolution of the proposed KDBMD are 5.29 nm/m(-1) and 0.11 m(-1), respectively. For backward bending (bending direction of 180 degrees), the sensitivity and resolution of the KDBMD are -3.11 nm/m(-1) and 0.12 m(-1), respectively. The temperature sensitivity of the KDBMD is 0.043 nm/degrees C. Furthermore, the performance of the KDBMD for knee-joint movement detection is compared with that of an inclinometer. The experimental results indicate that the data acquired from the KDBMD and the photoelectric encoder are consistent with regard to the accuracy and responsiveness. The proposed device, which is versatile and inexpensive to fabricate and can achieve temperature compensation, has potential for applications in gait analysis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据