4.6 Article

Biophysical regulations of transpiration and water use strategy in a mature Chinese pine (Pinus tabulaeformis) forest in a semiarid urban environment

期刊

HYDROLOGICAL PROCESSES
卷 36, 期 2, 页码 -

出版社

WILEY
DOI: 10.1002/hyp.14485

关键词

biophysical regulations; leaf stomata; meteorological factors; soil water availability; urban tree transpiration; water potential

资金

  1. China National Key RD Program [2017YFE0118100]
  2. National Science-Technology Support Plan Projects of China [2015BAD07B06-4]

向作者/读者索取更多资源

Urban trees and forests provide multiple ecosystem services for urban dwellers. This study monitored the sap flow of a Chinese pine plantation in a semi-arid urban environment and found that soil moisture played an important role in stand transpiration. The study also revealed the sensitivity of leaf stomata to vapor pressure deficit and solar radiation, and the reduction of canopy conductance under soil water stress.
Urban trees and forests provide multiple ecosystem services for urban dwellers. However, forest water use for these benefits has become one of the critical concerns in dryland regions where water is limited. Negative forest water use impacts could be reduced by selecting tree species with low rates of transpiration. However, the possible changes of urban tree transpiration and its biophysical controls are still unclear. This study monitored the sap flow of a 58-year-old Chinese pine (Pinus tabulaeformis) plantation in a semiarid urban environment of northern China. Soil moisture played an important role in stand transpiration (E-c). E-c had a strong positive relationship with vapour pressure deficit (VPD) and solar radiation (R-s) when soil water was sufficient. In addition, the sensitivity of leaf stomata to VPD was not related to leaf and branch water potential. Under soil water stress, E-c was significantly reduced by 63.1% (p < 0.001) and was weakly related to VPD and R-s. Canopy conductance (g(c)) was reduced (p < 0.001) by 74.3% due to leaf stomatal closure, and the sensitivity of leaf stomata to VPD was significantly increased (p < 0.05) with increasing leaf and branch water potential. Wind speed had no significant effects on E-c. P. tabulaeformis tended to be isohydric with a relatively constant midday leaf water potential (i.e. -2.46 to -2.92 MPa) and strong stomatal regulation as a function of soil water stress. However, slopes (0.53-0.56) of the linear relationship between m (dg(c)/dlnVPD) and reference canopy conductance were significantly lower than the widely recognized 0.6 (p < 0.001). Therefore, urban tree transpiration drivers and forest impacts need to be clarified to better understand the proper tradeoff between water consumption and ecological services for urban areas.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据