4.7 Article

Comparing the number and relevance of false activations between 2 artificial intelligence computer-aided detection systems: the NOISE study

期刊

GASTROINTESTINAL ENDOSCOPY
卷 95, 期 5, 页码 975-+

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.gie.2021.12.031

关键词

-

资金

  1. Fujifilm
  2. Boston Scientific
  3. Olympus
  4. Medtronic
  5. Ninepoint Medical
  6. Cosmo/Aries Pharmaceuticals

向作者/读者索取更多资源

The aim of this study was to validate a previously developed classification of false-positive (FP) activations and compare the performances of different brands of approved computer-aided detection (CADe) systems. The results showed that there was no significant difference in the number and causes of false activations between the two different brands of CADe systems. The use of standardized nomenclature provided comparable results.
Background and Aims: Artificial intelligence has been shown to be effective in polyp detection, and multiple computer-aided detection (CADe) systems have been developed. False-positive (FP) activation emerged as a possible way to benchmark CADe performance in clinical practice. The aim of this study was to validate a previously developed classification of FPs comparing the performances of different brands of approved CADe systems. Methods: We compared 2 different consecutive video libraries (40 video per arm) collected at Humanitas Research Hospital with 2 different CADe system brands (CADe A and CADe B). For each video, the number of CADe false activations, cause, and time spent by the endoscopist to examine the area erroneously highlighted were reported. The FP activations were classified according to the previously developed classification of FPs (the NOISE classification) according to their cause and relevance. Results: In CADe A 1021 FP activations were registered across the 40 videos (25.5 +/- 12.2 FPs per colonoscopy), whereas in CADe B 1028 were identified (25.7 +/- 13.2 FPs per colonoscopy; P = .53). Among them, 22.9 +/- 9.9 (89.8% in CADe A) and 22.1 +/- 10.0 (86.0% in CADe B) were because of artifacts from the bowel wall. Conversely, 2.6 +/- 1.9 (10.2% in CADe A) and 3.5 +/- 2.1 (14% in CADe B) were caused by bowel content (P = .45). Within CADe A each false activation required .2 +/- .9 seconds, with 1.6 +/- 1.0 FPs (6.3%) requiring additional time for endoscopic assessment. Comparable results were reported within CADe B with .2 +/- .8 seconds spent per false activation and 1.8 +/- 1.2 FPs per colonoscopy requiring additional inspection. Conclusions: The use of a standardized nomenclature provided comparable results with either of the 2 recently approved CADe systems.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据