4.5 Article

Inhibition of DNA amplification caused by metal in extracted bloodstains and in direct amplification

期刊

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.fsigen.2021.102598

关键词

DNA; Direct amplification; Metal; Inhibition; STR; SEM

资金

  1. Forensic Science Program at The Pennsylvania State University, PA, USA

向作者/读者索取更多资源

The study examined the inhibitory effects of copper and other metals on bloodstain deposition, as well as the efficiency of DNA profiling using different amplification methods. Direct amplification proved to be more effective in obtaining complete STR profiles compared to extraction methods, with copper composition showing limited impact on profile completeness.
Copper is a metal that is commonly found in many evidence types, such as weapons, and household items, that are often retrieved from crime scenes. We used copper and brass sheets, cartridge cases, and metal de ' cor items as substrates for deposition of blood to study inhibition induced by metals. Another objective was to compare the efficiency of STR profiling following extraction, quantification, amplification, and capillary electrophoresis with a direct amplification method which only requires amplification and capillary electrophoresis. Samples that were designated for extraction, were collected, extracted, and purified using the Qiagen EZ1 DNA Investigator (R) Kit. Direct amplification was performed using Copan microFLOQ (R) Direct Swabs to collect minute amount of blood. Complete STR profiles were obtained from 54% of the extracted samples and from 88% of directly amplified samples. Substrate type and amplification method (two-way ANOVA, F(5, 131) = 3.59, p = 4.50 x 10-3) impacted profile completeness but collection time did not (one-way ANOVA, F(1, 131) = 0.017, p = 0.90). Composition of the substrates was determined with scanning electron microscopy (SEM), and inhibition caused by copper was evaluated for each substrate. When substrate composition was analyzed in combination with amplification method, a substrate's copper percent was not associated with increased allelic dropout (one-way ANOVA, F(1, 176) = 0.70, p = 0.40) but amplification alone was statistically significant (one-way ANOVA, F(1, 176) = 40.64, p = 1.56 x 10-9). Using the Copan microFLOQ (R) Direct Swabs, inhibition induced by metal observed was not as pronounced. In addition, less variability in profile completeness was detected, profiles were generated within a very short period, and only minute amount of bloodstain was needed, allowing for additional analysis of the same samples. Our results directly quantify the effect of copper composition on DNA profiling and suggest that while copper percentage is an observational contributor to allele dropout it is not wholly responsible for these events.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据