4.5 Article

Residual Stresses from Incremental Hole Drilling Using Directly Deposited Thin Film Strain Gauges

期刊

EXPERIMENTAL MECHANICS
卷 62, 期 4, 页码 701-713

出版社

SPRINGER
DOI: 10.1007/s11340-022-00822-0

关键词

Thin-film strain gauges; Incremental hole-drilling method; Residual stress; Direct deposition; Temperature sensors; Sputtering

资金

  1. German Federation of Industrial Research Associations (AiF) [20626/N]

向作者/读者索取更多资源

This study investigates the application of directly deposited thin film strain gauges in the incremental hole drilling method. The results show that the residual stress depth profiles obtained from the directly deposited strain gauges match those obtained from conventional polymer foil-based strain gauges. The advantages of direct deposition include simplified zero depth setting and the ability to create various rosette designs for evaluating the strain field.
Background Commonly, polymer foil-based strain gauges are used for the incremental hole drilling method to obtain residual stress depth profiles. These polymer foil-based strain gauges are prone to errors due to application by glue. For example zero depth setting is thus often erroneous due to necessary removal of polymer foil and glue. This is resulting in wrong use of the calibration coefficients and depth resolution and thus leading to wrong calculations of the obtained residual stress depth profiles. Additionally common polymer foil-based sensors are limited in their application regarding e.g. exposure to high temperatures. Objective This paper aims at a first step into the qualification of directly deposited thin film strain gauges for use with the incremental hole drilling method. With the directly deposited sensors, uncertainties regarding the determination of calibration coefficients and zero depth setting due to the absence of glue can be reduced to a minimum. Additionally, new areas of interest such as the investigation of thermally sprayed metallic layers can be addressed by the sensors due to their higher temperature resilience and their component inherent minimal thickness. Methods For the first time, different layouts of directly deposited thin film strain gauges for residual stress measurements were manufactured on a stainless steel specimen. Strain measurements during incremental hole drilling using a bespoke hole drilling device were conducted. Residual stress depth profiles were calculated using the Integral method of the ASTM E837 standard. Afterwards, strain measurements with conventional polymer foil-based strain gauges during incremental hole drilling were conducted and residual stress depth profiles were calculated accordingly. Finally the obtained profiles were compared regarding characteristic values. Results The residual stress depth profiles obtained from directly deposited strain gauges generally match the ones obtained from conventional polymer foil based strain gauges. With the novel strain gauges, zero depth setting is simplified due to the absence of glue and polymer foil. With the direct deposition, a wide variety of rosette designs is possible, enabling a more detailed evaluation of the strain field around the drilled hole. Conclusions The comparative analysis of the obtained residual stress depth profiles shows the general feasibility of directly deposited strain gauges for residual stress measurements. Detailed investigations on uncertainty sources are still necessary.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。