4.7 Article

A deep learning-based automatic analysis of cardiovascular borders on chest radiographs of valvular heart disease: development/external validation

期刊

EUROPEAN RADIOLOGY
卷 32, 期 3, 页码 1558-1569

出版社

SPRINGER
DOI: 10.1007/s00330-021-08296-9

关键词

Heart valve diseases; Radiography; Cardiovascular system; Artificial intelligence; Deep learning

资金

  1. Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI) - Ministry of Health and Welfare, Republic of Korea [HI18C2383, HI18C0022]

向作者/读者索取更多资源

The study developed and validated a deep learning-based automatic CXR CB analysis algorithm (CB_auto) for diagnosing and quantitatively evaluating valvular heart disease (VHD). The CB_auto system provided highly reliable CB measurements that could be useful in both clinical practice and research.
Objectives Cardiovascular border (CB) analysis is the primary method for detecting and quantifying the severity of cardiovascular disease using posterior-anterior chest radiographs (CXRs). This study aimed to develop and validate a deep learning-based automatic CXR CB analysis algorithm (CB_auto) for diagnosing and quantitatively evaluating valvular heart disease (VHD). Methods We developed CB_auto using 816 normal and 798 VHD CXRs. For validation, 640 normal and 542 VHD CXRs from three different hospitals and 132 CXRs from a public dataset were assigned. The reliability of the CB parameters determined by CB_auto was evaluated. To evaluate the differences between parameters determined by CB_auto and manual CB drawing (CB_hand), the absolute percentage measurement error (APE) was calculated. Pearson correlation coefficients were calculated between CB_hand and echocardiographic measurements. Results CB parameters determined by CB_auto yielded excellent reliability (intraclass correlation coefficient > 0.98). The 95% limits of agreement for the cardiothoracic ratio were 0.00 +/- 0.04% without systemic bias. The differences between parameters determined by CB_auto and CB_hand as defined by the APE were < 10% for all parameters except for carinal angle and left atrial appendage. In the public dataset, all CB parameters were successfully drawn in 124 of 132 CXRs (93.9%). All CB parameters were significantly greater in VHD than in normal controls (all p < 0.05). All CB parameters showed significant correlations (p < 0.05) with echocardiographic measurements. Conclusions The CB_auto system empowered by deep learning algorithm provided highly reliable CB measurements that could be useful not only in daily clinical practice but also for research purposes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据