4.6 Article

Modified DC-Bus Voltage Balancing Algorithm for a Three-Level Neutral-Point-Clamped PMSM Inverter Drive With Reduced Common-Mode Voltage

期刊

IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS
卷 52, 期 1, 页码 278-292

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TIA.2015.2474307

关键词

Common-mode voltage (CMV); motor drives; permanent-magnet machines; three-level inverter

向作者/读者索取更多资源

This paper presents an improved dc-link voltage balancing algorithm for a three-level neutral-point-clamped inverter by considering phase current direction. Detailed studies on the effects of change in load current direction on the dc-link capacitor voltages are presented. A maximum value of power factor is numerically derived, above which it affects the capacitor voltage balancing capability. Compared with the previously presented research work, the inputs to the space-vector pulse width-modulation block are the three phase currents and the difference between the two capacitor voltages. Depending on the states of the two dc-link capacitor voltages and phase current direction, redundant voltage vector sequences are selected. The selected vectors keep the capacitor voltage deviations within 5% of the total dc-link voltage. Two zero switching vectors (i.e., PPP and NNN) are also removed from all subsectors of the earlier proposed strategy, which one used to produce higher common-mode voltages. Detailed simulation and experimental results are presented in this paper for a 6.0-kW surface permanent-magnet synchronous machine. Both the simulation and experimental results show the required performance of the proposed system.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据