期刊
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS
卷 63, 期 7, 页码 4233-4241出版社
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TIE.2016.2544243
关键词
Capacitor-voltage estimation; cascaded H-bridge (CHB) converter; photovoltaic (PV) system
In this paper, a cascaded H-Bridge (CHB)-multilevel converter (MC)-based photovoltaic (PV) system with no voltage or current sensors at the dc-side is proposed. Eliminating the dc-side sensors simplifies the hardware, leading to lower cost and higher reliability of the PV system. A novel scheme estimating the capacitors' voltages from the ac output voltage of the inverter is developed. The scheme allows replacing all dc-side voltage sensors by a single-voltage sensor at the ac-side of the converter. Furthermore, the dc current sensors, conventionally required for the maximum power point tracking (MPPT), are also eliminated. Instead, the outputs from the capacitors' voltage control systems are utilized for the MPPT. The effectiveness of the proposed dc-side sensorless system is experimentally demonstrated on a 2-kW single-phase seven-level CHB converter-based PV system.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐