4.2 Article

Atrial fibrillatory rate as predictor of recurrence of atrial fibrillation in horses treated medically or with electrical cardioversion

期刊

EQUINE VETERINARY JOURNAL
卷 54, 期 6, 页码 1013-1022

出版社

WILEY
DOI: 10.1111/evj.13551

关键词

AFR; arrhythmia; cardiology; ECG; electrophysiology; horse; surface electrocardiogram

资金

  1. Independent Research Fund Denmark [DFF-7017-00050]

向作者/读者索取更多资源

This study demonstrates that high atrial fibrillatory rate (AFR) is associated with the failure of quinidine cardioversion and recurrence of atrial fibrillation (AF) after successful electrical cardioversion. AFR, as a noninvasive marker obtained from surface ECG, can be clinically useful in predicting the probability of response to quinidine treatment and maintaining sinus rhythm (SR).
Background The recurrence rate of atrial fibrillation (AF) in horses after cardioversion to sinus rhythm (SR) is relatively high. Atrial fibrillatory rate (AFR) derived from surface ECG is considered a biomarker for electrical remodelling and could potentially be used for the prediction of successful AF cardioversion and AF recurrence. Objectives Evaluate if AFR was associated with successful treatment and could predict AF recurrence in horses. Study design Retrospective multicentre study. Methods Electrocardiograms (ECG) from horses with persistent AF admitted for cardioversion with either medical treatment (quinidine) or transvenous electrical cardioversion (TVEC) were included. Bipolar surface ECG recordings were analysed by spatiotemporal cancellation of QRST complexes and calculation of AFR from the remaining atrial signal. Kaplan-Meier survival curve and Cox regression analyses were performed to assess the relationship between AFR and the risk of AF recurrence. Results Of the 195 horses included, 74 received quinidine treatment and 121 were treated with TVEC. Ten horses did not cardiovert to SR after quinidine treatment and AFR was higher in these, compared with the horses that successfully cardioverted to SR (median [interquartile range]), (383 [367-422] vs 351 [332-389] fibrillations per minute (fpm), P < .01). Within the first 180 days following AF cardioversion, 12% of the quinidine and 34% of TVEC horses had AF recurrence. For the horses successfully cardioverted with TVEC, AFR above 380 fpm was significantly associated with AF recurrence (hazard ratio = 2.4, 95% confidence interval 1.2-4.8, P = .01). Main limitations The treatment groups were different and not randomly allocated, therefore the two treatments cannot be compared. Medical records and the follow-up strategy varied between the centres. Conclusions High AFR is associated with failure of quinidine cardioversion and AF recurrence after successful TVEC. As a noninvasive marker that can be retrieved from surface ECG, AFR can be clinically useful in predicting the probability of responding to quinidine treatment as well as maintaining SR after electrical cardioversion.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据