4.5 Article

Fully automated detection of focal cortical dysplasia: Comparison of MPRAGE and MP2RAGE sequences

期刊

EPILEPSIA
卷 63, 期 1, 页码 75-85

出版社

WILEY
DOI: 10.1111/epi.17127

关键词

artificial neural networks; epilepsy; focal cortical dysplasia; machine learning; morphometric analysis

资金

  1. research commission of the University Medical Center Freiburg

向作者/读者索取更多资源

The study showed that utilizing MP2RAGE sequences for FCD detection had higher sensitivity compared to using MPRAGE sequences. Additionally, incorporating cluster volume information helped differentiate between true and false positive results in MP2RAGE imaging.
Objective The detection of focal cortical dysplasia (FCD) in magnetic resonance imaging is challenging. Voxel-based morphometric analysis and automated FCD detection using an artificial neural network (ANN) integrated into the Morphometric Analysis Program (MAP18) have been shown to facilitate FCD detection. This study aimed to evaluate whether the detection of FCD can be further improved by feeding this approach with magnetization prepared two rapid acquisition gradient echoes (MP2RAGE) instead of magnetization-prepared rapid acquisition gradient echo (MPRAGE) datasets. Methods MPRAGE and MP2RAGE datasets were acquired in a consecutive sample of 32 patients with FCD and postprocessed using MAP18. Visual analysis and, if available, histopathology served as the gold standard for assessing the sensitivity and specificity of FCD detection. Out-of-sample specificity was evaluated in a cohort of 32 healthy controls. Results The sensitivity and specificity of FCD detection were 82.4% and 62.5% for the MPRAGE and 97.1% and 34.4% for the MP2RAGE sequences, respectively. Median volumes of true-positive voxel clusters were .16 ml for the MPRAGE and .52 ml for the MP2RAGE sequences compared to .08- and .04-ml volumes of false-positive clusters. With regard to cluster volumes, FCD detection was substantially improved for the MP2RAGE data when the estimated optimal threshold of .23 ml was applied (sensitivity = 72.9%, specificity = 83.0%). In contrast, the estimated optimal threshold of .37 ml for the MPRAGE data did not improve FCD lesion detection (sensitivity = 42.9%, specificity = 79.5%). Significance In this study, the sensitivity of FCD detection by morphometric analysis and an ANN integrated into MAP18 was higher for MP2RAGE than for MPRAGE sequences. Additional usage of cluster volume information helped to discriminate between true- and false-positive MP2RAGE results.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据