4.7 Article

Fatigue behaviour of non-welded wrapped composite joints for steel hollow sections in axial load experiments

期刊

ENGINEERING STRUCTURES
卷 249, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2021.113369

关键词

Wrapped composite joint; Bonded joint; CHS; Steel-composite; Fatigue experiments; GFRP; Crack growth; 3D DIC; Welded joint; Surface roughness

资金

  1. Dutch Research Council (NWO) [16949]
  2. China Scholarship Council (CSC) [201906260300]

向作者/读者索取更多资源

The study focuses on improving fatigue performance of circular hollow section (CHS) multi-membered structures through a novel wrapped composite jointing technology. Initial tests on the fatigue performance of wrapped composite joints were conducted, leading to the establishment of preliminary fatigue life predictions. Factors such as surface roughness of steel tubes, re-testing, and fatigue loading were investigated for their influence on the performance of wrapped composite joints.
Design and execution of fatigue load dominated circular hollow section (CHS) multi-membered structures, such as offshore jacket and floating structures for wind turbines, truss bridges, etc., is hinged on fatigue performance of critical welded joints. An innovative jointing technology of wrapped composite joint connects steel hollow sections by direct bonding through a fibre reinforced polymer composite wrap, which completely avoids welding and therefore has superior fatigue performance than welded joints. In this study first results on fatigue performance of the wrapped composite joints is presented. Tensile cyclic loading tests on wrapped composite X-joint specimens were carried out to characterise their fatigue performance under different constant amplitude load ranges and compare it to equivalent welded joints. In addition, the influence of surface roughness of steel tubes and re-testing (load history) on fatigue performance of wrapped composite joints, as well as the influence of fatigue loading on residual static resistance was investigated in experiments. Preliminary S-N curves of wrapped composite joints are established. The tests results showed that X45 wrapped composite joints exhibited steadier stiffness degradation and 10-100 times longer fatigue life than their welded equivalents. Through 3D DIC surface strain measurements and post-failure microscopic insights to cut specimens, different failure modes including debonding at glass fibre composite-to-steel interface, delamination/fracture of the composite layers and fracture of steel brace are distinguished. The relationship between joint stiffness degradation rates, crack propagation rates and nominal stress ranges in the brace are established, based on which a preliminary fatigue life prediction of wrapped composite joints can be made. The re-tested specimens exhibited superior fatigue performance than virgin ones, while specimens with poor steel surface roughness showed worse fatigue performance. After fatigue loading with 40% of stiffness degradation, the specimens were found to still have the potential to sustain its original static resistance.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据