4.7 Article

Rational design of high power density Blue Energy Harvester pressure retarded osmosis (PRO) membranes using artificial intelligence-based modeling and optimization

期刊

ENERGY CONVERSION AND MANAGEMENT
卷 253, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.enconman.2021.115160

关键词

Pressure retarded osmosis; Salinity gradient power; High power density membrane; Artificial intelligence; Machine learning; Inverse design

资金

  1. DST-SERB [CRG/2018/001538]

向作者/读者索取更多资源

The study used a data-driven approach to design optimal membranes and operating conditions for pressure retarded osmosis (PRO) and utilized artificial neural network (ANN) models to predict water flux and power density. It found that membrane properties and operating conditions were major contributing factors for the prediction, and optimization resulted in maximum water flux and power density.
The challenge in harvesting Salinity Gradient Power (SGP) through pressure retarded osmosis (PRO) requires design of high power density (PD) membranes and optimized process for operation. Recent studies show that for a feasible PRO operation the minimum net PD should be around 50 W/m2. In this study, a data-driven approach has been adopted for designing optimum membranes as well as operating conditions. 200 papers, from last decade, were extensively reviewed and 34 experimental research articles were shortlisted for possible data mining, to predict water flux (WF) and PD. Comprehensive screened/pre-processed data related to both membrane and process (16 inputs) was obtained from 18 articles amounting to 339 data points. Two artificial neural network (ANN) models were explored (i) Levenberg-Marquardt (ANN-LM), and (ii) Bayesian Regularization (ANN-BR) along with a combination of three different activation functions i.e., hyperbolic tangent sigmoid transfer function (Tan-Sigmoid), logarithmic sigmoid transfer function (Log-Sigmoid) in the input and output layers. Out of the six resulting combinations, the best performing combination was found to be Tan-Sigmoid activation function in both layers with ANN-BR model having an R2 value of 0.97 for WF and 0.98 for PD. Membrane properties like the type of membrane, thickness, and water permeability coefficient were found to be the major contributing factors for the prediction of WF while for PD, operating conditions such as applied pressure were found to play the major contributing factor (10-16 %). Optimization results yield a maximum WF of 147 LMH and PD of 87 W/m2. These results were compared with the solution diffusion (S-D) model.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据