Load shifting and energy conservation using smart thermostats in contemporary high-rise residential buildings: Estimation of runtime changes using field data

期刊

ENERGY AND BUILDINGS
卷 255, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2021.111644

关键词

Demand management; Energy flexibility; HVAC; Buildings; Residential; Connected Thermostats

资金

  1. Enbridge
  2. Toronto Hydro
  3. Natural Sciences and Engineering Research Council of Canada (NSERC) [RGPIN-2016-06325]
  4. The Atmospheric Fund (TAF)
  5. Independent Electricity System Oper-ator (IESO)
  6. Ontario Centres of Excellence (OCE) Voucher in Innovation Program (VIP)

向作者/读者索取更多资源

As the urban population grows, so does the number of highrise residential buildings. Heating, ventilation, and air conditioning (HVAC) account for over half of the energy use in these buildings in Canada. Smart thermostats offer an opportunity to conserve energy and shift electricity load through HVAC control modifications. The study tested three thermostat control strategies and found that occupancy-based control reduced HVAC runtime, while load shifting control was not effective at reducing peak period loads.
As the proportion of the population who resides in urban centers grows, the number of dwellings in highrise residential buildings is also increasing. In Canada, heating, ventilation, and air conditioning (HVAC) typically accounts for over half of all energy use in this building type and, as such, consideration of these loads is key to effective energy demand-side management. Smart thermostats present a new opportunity conserve energy and shift electricity load to off-peak periods in these buildings through modifications to HVAC control strategies. In this study, three thermostat control strategies were tested in 49 suites across two contemporary high-rise residential buildings: 1) baseline operation (thermostat operating as a standard programmable thermostat); 2) occupancy-based control (thermostat operating using an occupancy reactive control strategy); 3) load shifting control (thermostat operating using a pre-conditioning strategy). HVAC runtime data was collected from smart thermostats installed in the suites and was used to develop data-driven regression models to estimate baseline suite HVAC runtime based on weather conditions and suite characteristics. Thermostat-measured HVAC runtime data for periods in which occupancy-based or load shifting control strategies were in use in the suite was then compared with estimated baseline runtime for similar outdoor conditions. Occupancy-based control was found to reduce HVAC system runtime during the cooling seasonby 5.9% +/- 46% on average. On aggregate, the load shifting control strategy was not effective at reducing peak period HVAC load during the cooling season. The strategy was able to reduce peak period loads in a subset of suites substantially, which may be leveraged to reduce electricity demand during capacity-constrained periods of grid operation, however, based on marginal emissions factors for Ontario's electricity grid, even in these suites, the strategy was not effective in reducing GHG emissions overall. (c) 2021 Elsevier B.V. All rights reserved.