4.7 Article

Urban building energy model: Database development, validation, and application for commercial building stock

期刊

ENERGY AND BUILDINGS
卷 248, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2021.111175

关键词

Urban building energy model; Urban database; Image processing; Energy simulation; Energy conservation; Building archetype; Commercial buildings

资金

  1. National Science Foundation [1934824]
  2. Div Of Chem, Bioeng, Env, & Transp Sys
  3. Directorate For Engineering [1934824] Funding Source: National Science Foundation

向作者/读者索取更多资源

The study proposes a structure using commercial buildings to improve reproducibility of urban building energy models and introduces an innovative framework for facade reconstruction through photogrammetry and image processing. Twenty archetypes were identified in commercial buildings of different use types, showing discrepancies in energy use among buildings with similar use types.
Achieving citywide building energy reduction goals require extensive understanding of energy use at scale, which is challenging due to scarce and disparate data. Despite attention to urban building energy models (UBEM), unexplored aspects and missing details in this emerging field have remained, including further exploring non-homogenous commercial buildings, providing a detailed structure to create UBEMs for replication purposes, and developing methods to mitigate data scarcity and dependency. In this study, a structure is proposed using commercial buildings in Pittsburgh, Pennsylvania. We provide a description of an archetype library with relevant sources to improve reproducibility and describe a novel framework to create a database focusing on facade reconstruction through photogrammetry and image processing. For our UBEM, twenty archetypes that comprised eight commercial use types were identified. The average annual energy use intensity was estimated between 74 and 1302 kWh/m(2) for different use types. The simulation results also showed discrepancy in energy use of the buildings with similar use types. Validating the results utilizing actual data revealed an overall 7% error. Employing the model to evaluate energy conservation strategies showed energy use reduction of 2-5% for the entire stock. Outcomes of this research can aid policy makers in instituting energy goals and efficiency regulations. (C) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据