Data driven model for heat load prediction in buildings connected to District Heating by using smart heat meters

期刊

ENERGY
卷 239, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.energy.2021.122318

关键词

Load forecasting; Heat meters; Data-driven model; Building; District Heating

向作者/读者索取更多资源

This paper introduces a data-driven model for characterizing and predicting heating demand in buildings connected to a District Heating network. The model utilizes various climatic variables, time factors, and data from smart meters to accurately forecast heat loads. With low computational cost and high accuracy, the model is suitable for deployment over large building datasets.
An accurate characterization and prediction of heat loads in buildings connected to a District Heating (DH) network is crucial for the effective operation of these systems. The high variability of the heat production process of DH networks with low supply temperatures and derived from the incorporation of different heat sources increases the need for heat demand prediction models. This paper presents a novel data-driven model for the characterization and prediction of heating demand in buildings connected to a DH network. This model is built on the so-called Q-algorithm and fed with real data from 42 smart energy meters located in 42 buildings connected to the DH in Tartu (Estonia). These meters deliver heat consumption data with a 1-h frequency. Heat load profiles are analysed, and a model based on supervised clustering methods in combination with multiple variable regression is proposed. The model makes use of four climatic variables, including outdoor ambient temperature, global solar radiation and wind speed and direction, combined with time factors and data from smart meters. The model is designed for deployment over large sets of the building stock, and thus aims to forecast heat load regardless of the construction characteristics or final use of the building. The low computational cost required by this algorithm enables its integration into machines with no special requirements due to the equations governing the model. The data-driven model is evaluated both statistically and from an engineering or energetic point of view. R-2 values from 0.70 to 0.99 are obtained for daily data resolution and R-2 values up to 0.95 for hourly data resolution. Hourly results are very promising for more than 90% of the buildings under study. (C) 2021 The Authors. Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据