4.3 Article

Comparison of surface- and voxel-based registration on the mandibular ramus for long-term three-dimensional assessment of condylar remodelling following orthognathic surgery

期刊

DENTOMAXILLOFACIAL RADIOLOGY
卷 51, 期 4, 页码 -

出版社

BRITISH INST RADIOLOGY
DOI: 10.1259/dmfr.20210499

关键词

Three-Dimensional Imaging; Cone-Beam Computed Tomography; Computer-Assisted Surgery; Temporomandibular Joint; Orthognathic Surgery

向作者/读者索取更多资源

The present study aimed to validate and compare the accuracy and reliability of surface- and voxel-based registration for long-term three-dimensional evaluation of condylar remodelling following Orthognathic Surgery. The results showed that surface-based registration was more accurate and reliable than voxel-based registration. However, the choice of reference structure may affect the performance difference.
Objectives: The purpose of the present study was to validate and compare the accuracy and reliability of surface- and voxel-based registration on the mandibular rami for long-term three-dimensional (3D) evaluation of condylar remodelling following Orthognathic Surgery. Methods: The mandible was 3D reconstructed from a pair of superimposed pre- and postoperative (two years) cone-beam computerized tomography scans and divided into the condyle, and 21 ramal regions. The accuracy of surface- and voxel-based registration was measured by the absolute mean surface distance of each region after alignment of the pre- and postoperative rami. To evaluate the reliability, mean absolute differences and intraclass correlation coefficients (ICC) were calculated at a 95% confidence interval on volumetric and surface distance measurements of two observers. Paired t-tests were applied to statistically evaluate whether the accuracy and reliability of surface- and voxel-based registration were significantly different (p < 0.05). Results: A total of twenty subjects (sixteen female; four male; mean age 27.6 years) with class II malocclusion and maxillomandibular retrognathia, who underwent bimaxillary surgery, were included. Surface-based registration was more accurate and reliable than voxel-based registration on the mandibular ramus two years post-surgery (p < 0.05). The interobserver reliability of using surface-based registration was excellent, ICC range [0.82-1.00]. For voxel-based registration, the interobserver reliability ranged from poor to excellent [0.00-0.98]. The measurement error introduced by applying surface-based registration for assessment of condylar remodelling was considered clinical irrelevant (1.83% and 0.18 mm), while the measurement error introduced by voxel-based registration was considered clinical relevant (5.44% and 0.52 mm). Conclusions: Surface-based registration was proven more accurate and reliable compared to voxel-based registration on the mandibular ramus for long-term 3D assessment of condylar remodelling following Orthognathic Surgery. However, importantly, the performance difference may be caused by an inappropriate reference structure, proposed in the literature, and applied in this study.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据