4.7 Article

Flexural strengthening of RC beams with BFRP or high strength steel bar-reinforced ECC matrix

期刊

CONSTRUCTION AND BUILDING MATERIALS
卷 303, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.conbuildmat.2021.124404

关键词

Flexural strengthening; RC beams; BFRP bars; High-strength steel (HSS) bars; Engineered Cementitious Composites (ECC); Flexural capacity

资金

  1. Promotion Program for Young and Middle-aged Teacher in Science and Technology Research of Huaqiao University [ZQN-PY514]
  2. China Postdoctoral Science Foundation [2020M682098]

向作者/读者索取更多资源

This study investigated the flexural behavior of reinforced concrete beams strengthened with BFRP or HSS bars, finding that BFRP bars dominated in the failure of beams while HSS bars significantly improved flexural capacity due to their high stiffness and strength. Comparisons between ECC and polymer mortar matrices showed that ECC resulted in larger enhancements in load capacities, confirming the excellent strain compatibility of BFRP bars and ECC matrix. Additionally, a flexural theoretical analysis was proposed and verified through experimental results.
This paper has investigated the flexural behavior of reinforced concrete (RC) beams strengthened with BFRP (basalt fiber reinforced polymer) or HSS (high strength steel) bar reinforced ECC matrix. A total of six strengthened RC beams and one control RC beam were tested under four-point bending up to their failure. The test variables included the cement matrix (ECC and polymer mortar), the reinforcements type (BFRP and HSS bars) as well as the reinforcement ratio (0.94% and 1.41%) of the strengthening layer. Two failure modes including the rupture of BFRP bars and the rupture of ECC matrix followed by the slippage of the steel bars were obtained in the strengthened beams. The rupture of BFRP bars dominated the failure of beams strengthened with BFRP bar reinforced cement matrix owing to the limited tensile strength of BFRP bars, and the percentage of enhancement in flexural capacity ranged from 18.6% to 47.8% compared with the control beam. The beams strengthened with HSS bar reinforced ECC matrix all failed due to the rupture of ECC matrix followed by the slippage of HSS bars, mainly owing to the high stiffness and strength of the HSS bars, leading to larger enhancements in flexural capacity at a range of 60.0-75.6%. In addition, a beam strengthened with BFRP bar reinforced polymer mortar was also tested with the purpose of conforming the advantage of ECC over polymer mortar as the matrix of the strengthening layer. The test results showed that the application of ECC matrix with BFRP bars resulted in larger enhancement in the yield and ultimate loads compared to the use of polymer mortar matrix. The difference between the two strengthening systems confirmed the excellent strain compatibility of BFRP bars and ECC matrix. Finally, a flexural theoretical analysis based on three possible failure cases was proposed, and its reliability was verified through comparing the test results and the theoretical predictions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据