4.7 Article

A fast tool for the parametric analysis of human body exposed to LF electromagnetic fields in biomedical applications

期刊

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.cmpb.2021.106543

关键词

Bio-electromagnetism; Computational electromagnetics; Electromagnetic (EM) analysis fast methods; Integral equations; Magnetic resonance imaging (MRI); Uncertainty quantification

资金

  1. EMPIR Program
  2. European Union

向作者/读者索取更多资源

This article presents a numerical procedure for analyzing the interaction between electromagnetic fields and biological tissues. The proposed method reduces the computational burden by voxelizing the human body and taking advantage of regular discretization. It also utilizes iterative preconditioned solvers and model order reduction techniques. The efficiency of the method is demonstrated through practical model problems.
A numerical procedure for analyzing electromagnetic (EM) fields interactions with biological tissues is presented. The proposed approach aims at drastically reducing the computational burden required by the repeated solution of large scale problems involving the interaction of the human body with EM fields, such as in the study of the time evolution of EM fields, uncertainty quantification, and inverse problems. The proposed volume integral equation (VIE), focused on low frequency applications, is a system of integral equations in terms of current density and scalar potential in the biological tissues excited by EM fields and/or electrodes connected to the human body. The proposed formulation requires the voxelization of the human body and takes advantage of the regularity of such discretization by speeding-up the computational procedure. Moreover, it exploits recent advancements in the solution of VIE by means of iterative preconditioned solvers and ad hoc parametric Model Order Reduction techniques. The efficiency of the proposed tool is demonstrated by applying it to a couple of realistic model problems: the assessment of the peripheral nerve stimulation, performed in terms of evaluation of the induced electric field, due to the gradient coils of a magnetic resonance imaging scanner during a clinical examination and the assessment of the exposure to environmental fields at 50 Hz of live-line workers with uncertain properties of the biological tissues. Thanks to the proposed method, uncertainty quantification analyses and time domain simulations are possible even for large scale problems and they can be performed on standard computers and reasonable computation time. Sample implementation of the method is made publicly available at https://github.com/UniPD-DII-ETCOMP/BioMOR. (C) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据