4.5 Article

Comparison of five rotary systems regarding design, metallurgy, mechanical performance, and canal preparation-a multimethod research

期刊

CLINICAL ORAL INVESTIGATIONS
卷 26, 期 3, 页码 3299-3310

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00784-021-04311-x

关键词

Bending load; Differential scanning calorimetry; Endodontics; Micro-CT; Nickel-titanium alloy; Root canal therapy; Scanning electron microscopy; Torsional strength

资金

  1. CENIMAT/i3N by FCT-Fundacao para a Ciencia e a Tecnologia, I.P. within the scope of Multiannual Financing of RD Units [UIDB/50025/2020-2023]

向作者/读者索取更多资源

The study compared 5 rotary systems in terms of design, material, mechanical performance, and canal preparation, revealing differences in instrument geometry, surface finishing, and phase transformation temperatures. However, consistent results were observed in the untouched root canal walls after preparation with the tested systems.
Objectives To compare the design, metallurgy, mechanical performance, and canal preparation of 5 rotary systems. Material and methods A total of 735 25-mm NiTi instruments (sizes 0.17[0.18]/.02v, 0.20/.04v, 0.20/.07v, 0.25/.08v, 0.30/.09v) from ProTaper Gold, ProTaper Universal, Premium Taper Gold, Go-Taper Flex, and U-File systems were compared regarding overall geometry and surface finishing (stereomicroscopy and scanning electron microscopy), nickel and titanium ratio (energy-dispersive spectroscopy), phase transformation temperatures (differential scanning calorimetry), mechanical performance (torsional and bending tests), and unprepared canal surface (micro-CT). One-way ANOVA and Mood's median tests were used for statistical comparisons with a significance level set at 5%. Results Stereomicroscopic analysis showed more spirals and high helical angles in the Premium Taper Gold system. All sets of instruments had symmetrical spirals, no radial lands, no major defects, and an almost equiatomic ratio between nickel and titanium elements, while differences were observed in their tips' geometry and surface finishing. At room temperature (20 degrees C), DSC test revealed martensitic characteristics for ProTaper Gold and Go-Taper Flex, and mixed austenite plus R-phase for the Premium Taper Gold, while ProTaper Universal and U-Files had full austenitic characteristics. Overall, larger instruments had higher torque resistance and bending load values than smaller ones, while a lack of consistency and mixed values were observed in the angle of rotation. The 0.25/.08v and 0.30/.09v instruments of ProTaper Universal and U-File had the highest maximum torques, the lowest angles of rotation, and the highest bending loads than other tested systems (P < .05). No significant difference was noted regarding the untouched root canal walls after preparation with the tested systems (P > .05). Conclusions Although differences observed in the overall geometry and phase transformation temperatures have influenced the results of mechanical tests, unprepared canal surface areas were equivalent among systems.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据