4.7 Article

Leak Detection, Size Estimation and Localization in Pipe Flows

期刊

IEEE TRANSACTIONS ON AUTOMATIC CONTROL
卷 61, 期 1, 页码 246-251

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TAC.2015.2434031

关键词

Distributed parameter systems; fluid flow systems; leak detection; linear systems

向作者/读者索取更多资源

We design a leak detection system consisting of an adaptive observer based on a set of two coupled one dimensional first order hyperbolic partial differential equations governing the flow dynamics. It is assumed that measurements are only available at the inlet and outlet of the pipe. Convergence properties are provided showing that the leak size estimation problem can be tackled independently from how the leak is distributed along the pipe. This is key to obtaining a simple estimation scheme for the leak location. Simulations are provided to demonstrate the ability of the system to detect, quantify and locate leaks.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据