Review of techniques, challenges, and new developments for calcium isotope ratio measurements

期刊

CHEMICAL GEOLOGY
卷 581, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.chemgeo.2021.120398

关键词

Calcium isotopes; Chemical purification; Double spiking; Mass spectrometry; Reference standards

资金

  1. DST [SR/FTP/ES-72, SR/S4/ES-650/2012]
  2. MoES [MOES/PAMC/HC/41/2013PC-II]
  3. [NSF-EAR0723151]

向作者/读者索取更多资源

Calcium isotope measurements are conducted using various mass spectrometers, such as Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS), each with its own advantages and disadvantages for analyzing different types of samples. Recent advances in automation and new technologies have improved sample throughput and measurement precision, but further refinement of standards and comparison methods is needed.
Calcium isotope meaurements apply to problems spanning the 'cosmos to benthos.' Fractionation, source mixing, radioactive decay, and nucleosynthetic processes cause variations in Ca isotope ratios, which can be measured using different types of mass spectrometers. Early measurements employed thermal ionization mass spectrometry (TIMS), which continues to be the most common and precise reference technique. An increasing number of studies use multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS). Both TIMS and MC-ICPMS can yield high-quality data for delta(44/40) Ca and delta Ca-44/42, respectively, but wide ranges in precision exist. Sample size requirements are lower for TIMS, but MC-ICPMS offers faster throughput. Both techniques require purifying Ca by ion-exchange chromatography when analyzing samples with complex matrices. In-situ techniques, like laser ablation MC-ICPMS (LA-MC-ICPMS) and secondary ion mass spectrometry (SIMS), do not require purification. In-situ techniques provide high spatial resolution, but LA-MC-ICPMS and (nano)-SIMS suffer from relatively poor precision compared to TIMS and MC-ICPMS, and the methods lack well-characterized standards, which are essential for comparing datasets. The past few years have seen advances in Ca purification techniques, including automated methods that accelerate sample throughput. The next generation of Ca purification techniques should focus on complete purification and quantitative separation of low-Ca samples. Application of collision-cell technology for suppressing Ar-related molecular isobaric interferences will improve quantification of Ca-40 using certain MC-ICPMS models. Similarly, development of new amplifier technology will foster high-precision Faraday cup measurements of low abundance Ca isotopes. Adopting common reference materials, including newly developed standards with complex matrices, would signficantly aid inter-laboratory comparisons, method development, and data compilation efforts. In general, at least two widely-used standards should be measured along with unknown samples to confirm data quality, as well as improve utilization of published Ca isotope datasets by a broader community.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据