The corona discharge process in a wire-plate device under foggy condition is significantly influenced by charged microscale fog droplets in the air and macroscale droplets hanging on the electrodes. By designing a two-stage electrostatic fog collector with optimized electrode placement, a collection efficiency of over 90% can be achieved.
The corona discharge process in a wire-plate device under foggy condition is experimentally and numerically investigated. It is found that the corona discharge process in foggy air is obviously influenced by the charged microscale fog droplets in air and the macroscale droplets hanging on the electrodes. A numerical model is established and the simulation results indicate that charged fog droplets in air restrain the corona discharge and large droplets hanging on electrodes increase the discharge current. A two-stage electrostatic fog collector consisting of discharge, repelling and collection electrodes is designed. A collection efficiency of more than 90% is achieved. Collection efficiencies of several electrostatic fog collectors with different structures are experimentally and numerically evaluated. The results show that placing the collection planes along the wind direction and setting the discharge and repelling electrodes between the collection electrodes in the electrostatic fog collector are conducive to improving the collection efficiency. CO 2021 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据