4.6 Article

Seismic behavior of RC moment resisting structures with concrete shear wall under mainshock-aftershock seismic sequences

期刊

BULLETIN OF EARTHQUAKE ENGINEERING
卷 20, 期 2, 页码 1087-1114

出版社

SPRINGER
DOI: 10.1007/s10518-021-01291-x

关键词

Mainshock-aftershock; Seismic sequences; Shear wall; Reinforced concrete; Seismic behavior; Nonlinear behavior; Ratio of aftershock PGA to mainshock PGA

向作者/读者索取更多资源

This study examines the seismic behavior of reinforced concrete moment-resisting structures with concrete shear walls under seismic sequences. It finds that the high lateral stiffness and elastic behavior of the shear walls have little effect on short structures but significantly increase displacement in medium height structures. The ratio of aftershock PGA to mainshock PGA is a determinative parameter for structural behavior under seismic sequences.
A structure may be subject to several aftershocks after a mainshock. In many seismic design provisions, the effect of the seismic sequences is either not directly considered or has been underestimated. This study examined the seismic behavior of reinforced concrete (RC) moment-resisting structures with concrete shear walls under seismic sequences. Two three-dimensional structures of short and medium height were designed and analyzed under seven real mainshock-aftershock seismic sequences. The models were loaded and designed according to the Iranian seismic code (4th ed.; Standard No. 2800) and ACI-318. The structures were analyzed using the nonlinear explicit finite element method. The maximum displacement, inter-story drift ratio, residual displacement, and ratio of aftershock PGA to mainshock PGA were investigated and assessed. Because of the high lateral stiffness of the shear walls in addition to their completely elastic behavior, the aftershocks did not increase the inter-story drift ratio or relative displacement in the short structure model. The medium height model under the seismic sequences showed a significant growth in the relative displacement (roughly 25% in some cases), inter-story drift ratio, plastic strain, and residual displacement (42.22% growth on average) compared to the structure that was only subjected to the mainshock. Remarkably, in some cases, the aftershock doubled the residual displacement. Unlike the moment-resisting frames under seismic sequences, the models showed no significant growth in the drift ratio with an increase in height. Assessments indicated that the ratio of aftershock PGA to mainshock PGA is a determinative parameter for structural behavior under seismic sequences, such that high values of this ratio (> 0.6) caused significant increases in the residual and relative displacements.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据