4.7 Article

Experimental investigation on environmental control of a 50-person mine refuge chamber

期刊

BUILDING AND ENVIRONMENT
卷 210, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2021.108667

关键词

Mine refuge chamber; Human metabolic rate; Air quality; Ambient temperature; Relative humidity

资金

  1. National Natural Science Foundation of China [52168013, 51908080]
  2. State Key Laboratory of the Gas Disaster Detecting, Preventing and Emergency Controlling, affiliated to Chongqing Research Institute of China, Coal Technology & Engineering Group

向作者/读者索取更多资源

In this research, the air quality and thermal environment of mine refuge chambers (MRC) were evaluated to determine their impact on the safety of refugees. The study found that the metabolic rates of oxygen, carbon dioxide, and heat have significant implications for the environmental control measures in MRC. Chemical adsorbents and mine compressed air were also investigated for their potential use in CO2 scrubbing and dehumidification, respectively.
Air quality and thermal environment of mine refuge chamber (MRC) are very important to determine the physical safety of refugees. Accurately assessing the environmental load and taking reasonable measures are critical to achieve the environmental control goals of MRC. In order to evaluate the metabolic parameters of occupants and the effectiveness of environmental control measures in a MRC, in this research, 50 adult men entered a MRC laboratory for an 8-h test. During the test, the compressed O2 cylinders and air purification devices were used to ensure the indoor air quality. The possibility of using chemical adsorbents to passively scrub CO2 and the performance of dehumidification by mine compressed air (MCA) were also investigated by simulation experiments. The results indicated that: (1) The per capita metabolic rates of O2, CO2 and heat during the refuge process are 0.34-0.37 L/min, 0.34 L/min and 117-128 W, respectively. (2) When Ca(OH)2 particles are used as CO2 adsorbent, the air purification device has both dehumidification and CO2 scrubbing functions, and three air purification devices could make the CO2 concentration below 0.8% with the relative humidity below 76%. When Ca(OH)2 particles are packaged to passively scrub CO2, the amount of adsorbent may increase significantly. (3) When MCA is used for dehumidification in a MRC, the air volume of 0.15 m3/min per capita could maintain the relative humidity close to 60%. (4) In the early stage of disaster avoidance, the indoor ambient temperature rises rapidly within 1 h followed by a slight increase.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据