4.7 Article

Performance gaps of sustainability features in green award-winning university buildings

期刊

BUILDING AND ENVIRONMENT
卷 207, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2021.108417

关键词

Green buildings; Sustainability; Rainwater harvesting; Photovoltaic panels; Smart buildings

资金

  1. Newcastle University estates
  2. UKRI via the Global Challenges Research Fund (GCRF) [ES/S008179/1]
  3. ESRC [ES/S008179/1] Funding Source: UKRI

向作者/读者索取更多资源

Sustainability certifications encourage technologies to save resources, but actual performance often falls short due to technical and social issues. Continuous monitoring of building water consumption proves to be an effective solution for resource and cost savings.
Sustainability certifications like BREEAM, LEED, and China's sustainable green building award certification scheme encourage installation of technologies that save mains water and grid electricity. Among these are rainwater harvesting systems, ultralow water use appliances, photovoltaic panel systems, and intelligent building management systems. In reviewing the performance of two award-winning university buildings over respective periods of sixteen and four years, we found that such systems delivered only 28-71% of their potential resource savings. These performance gaps arose from various technical and social issues (pump failures, tank leakages, poor alignment of demand and supply with limited storage, low photovoltaic panel efficiency, poor user acceptance, etc.), but the consequences were exacerbated by inadequate asset management that resulted in long system downtimes, in some cases for 2-5 years. Repair, maintenance, and upgrading expenses then combined with lower than anticipated water and electricity bill savings that ultimately meant that, for the most part, there was no prospect of earning a return on capital expenditures. Continuous monitoring of building water consumption by an external service provider was the most effective resource and cost saving solution in this study, as it required no capital expenditure, and revealed a 1640 l/h leakage, without putting high demands on the building management. In contrast, little value was obtained from 25 water-related sensors installed as part of a building-as-a-lab project because of inadequate post hand-over support. Robust post-commissioning operation should become a key criterion for sustainable building innovation, and this should be reflected in green awards and rating systems.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据