4.7 Article

Impact of atmospherical stability and intra-hour variation of meteorological data in the variability of building air change rates

期刊

BUILDING AND ENVIRONMENT
卷 207, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2021.108528

关键词

Air infiltration; Meteorological data; Airtightness; Air change rate; Atmospheric stability; Wind shear coefficient

资金

  1. CONSTRUCT -Instituto de I&D em Estruturas e Construcoes - national funds through the FCT/MCTES (PIDDAC) [UIDB/04708/2020, UIDP/04708/2020]
  2. FCT - Fundacao para a Ciencia e a Tecnologia through the Doctoral Programme EcoCoRe [PD/BD/135162/2017]
  3. Fundação para a Ciência e a Tecnologia [PD/BD/135162/2017] Funding Source: FCT

向作者/读者索取更多资源

In contrast with structural engineering, the proper assessment and modeling of air change rates in natural ventilation and infiltration require the use of all input variables. Existing modeling methods in infiltration research overlook the intra-hour variability of meteorological variables and assume unchanged neutral atmospheric conditions, which affects the calculated airflows. This study details and quantifies these effects in a representative case study of a single-family dwelling in a Southern European climate.
In contrast with structural engineering, where the focus for design is on extreme values, for the proper assessment and modelling of air change rates in natural ventilation and infiltration, one must use the full range of input variables. Most of the modelling in infiltration research relies on hourly datasets for air infiltration balance. This consideration overlooks the intra-hour variability on meteorological variables. Additionally, it is customary to assume unchanging neutral atmospheric conditions when modelling, which affects the calculated airflows. This work intends to detail and quantify these effects in a case study representative of an average single-family dwelling in a Southern European climate setup. By comparing four setups with an increasing degree of complexity, a median of 0.04 h(-1) of the hourly standard deviations in air change rates (ACH) is attributed to the time step effect. Approximately 43% of the occurrences experienced non-neutral atmospheric stability, skewing for stable conditions. This effect contributed to differences in the ACHs ranging from-0.202 to 0.131 h(-1) at the 5% and 95% quantiles. Overall, by using hourly uniform distributions and smart sampling of meteorological variables, one ensures that the values in between and others potentially occurring around the boundaries are being considered for air change rates calculation, and therefore providing a more detailed picture of actual conditions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据