4.0 Article

Comparison of the sit-up test and head-up tilt test for assessing blood pressure and hemodynamic responses in healthy young individuals

期刊

BLOOD PRESSURE MONITORING
卷 27, 期 2, 页码 79-86

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MBP.0000000000000570

关键词

cardiac output; cardiography; sitting position; systolic blood pressure; total peripheral resistance

资金

  1. [18K17730]
  2. [21K17489]

向作者/读者索取更多资源

This study aims to compare the differences in blood pressure and hemodynamic responses between the sit-up test and the head-up tilt test. The results showed that the increase in systolic blood pressure was greater in the sit-up test, while the increase in heart rate and the reduction in stroke volume were smaller. The increase in blood pressure variables was significantly associated with the increase in total peripheral resistance.
Objective The sit-up test is used to assess orthostatic hypotension, without the use of a tilt table, in populations who are unable to stand. The primary objective of this study was to determine the differences in blood pressure and hemodynamic responses between the sit-up and head-up tilt tests. The secondary objective was to determine the hemodynamic responses related to changes in blood pressure during each test. Methods Nineteen healthy volunteers (nine males, aged 24.3 +/- 2.4 years) underwent the sit-up and head-up tilt tests. Systolic and diastolic blood pressure, heart rate, stroke volume, cardiac output, and total peripheral resistance were measured. Results The increase in systolic blood pressure (15 +/- 9 vs. 8 +/- 8 mmHg) was greater, while the increase in heart rate (8 +/- 5 vs. 12 +/- 8 bpm) and reduction in stroke volume (-17 +/- 10 vs. -21 +/- 10 ml) were smaller during the sit-up test than during the head-up tilt test (P < 0.05). Additionally, the increases in blood pressure variables were significantly associated with the increase in total peripheral resistance (P < 0.05), but not with changes in other hemodynamic variables in both tests. Conclusion Although the magnitudes of changes in systolic blood pressure, heart rate, and stroke volume differed between the tests, the hemodynamic variable related to changes in blood pressure was the same for both tests. These results may contribute to the clinical application of the sit-up test for identifying the presence and hemodynamic mechanisms of orthostatic hypotension.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据