4.8 Article

A mask-based diagnostic platform for point-of-care screening of Covid-19

期刊

BIOSENSORS & BIOELECTRONICS
卷 192, 期 -, 页码 -

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2021.113486

关键词

Exhaled breath condensate (EBC); Aptamers; SARS-CoV-2; Detection; Electrochemistry; Real-time reverse-transcription polymerase; chain reaction (RT-PCR)

资金

  1. I-SITE via the COVID task force
  2. Hauts-de-France region via ANR Resilience (CorDial-FLU)
  3. European Union [101016038]
  4. Centre National de la Recherche Scientifique (CNRS), the University of Lille

向作者/读者索取更多资源

This study introduces a novel concept of using exhaled breath condensate (EBC) collected by a mask-based sampling device and detected with an electrochemical biosensor for fast and specific detection of COVID-19. Results showed detection of SARS-CoV-2 in samples from positive patients, and the electrochemical biosensor was able to detect viral particles, providing information about the infectivity state of the patients.
Diagnostics of SARS-CoV-2 infection using real-time reverse-transcription polymerase chain reaction (RT-PCR) on nasopharyngeal swabs is now well-established, with saliva-based testing being lately more widely implemented for being more adapted for self-testing approaches. In this study, we introduce a different concept based on exhaled breath condensate (EBC), readily collected by a mask-based sampling device, and detection with an electrochemical biosensor with a modular architecture that enables fast and specific detection and quantification of COVID-19. The face mask forms an exhaled breath vapor containment volume to hold the exhaled breath vapor in proximity to the EBC collector to enable a condensate-forming surface, cooled by a thermal mass, to coalesce the exhaled breath into a 200-500 mu L fluid sample in 2 min. EBC RT-PCR for SARS-CoV-2 genes (E, ORF1ab) on samples collected from 7 SARS-CoV-2 positive and 7 SARS-CoV-2 negative patients were performed. The presence of SARS-CoV-2 could be detected in 5 out of 7 SARS-CoV-2 positive patients. Furthermore, the EBC samples were screened on an electrochemical aptamer biosensor, which detects SARS-CoV-2 viral particles down to 10 pfu mL-1 in cultured SARS-CoV-2 suspensions. Using a turn off assay via ferrocenemethanol redox mediator, results about the infectivity state of the patient are obtained in 10 min.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据