Estimating the accumulative dose uncertainty for intracavitary and interstitial brachytherapy

期刊

BIOMEDICAL ENGINEERING ONLINE
卷 20, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12938-021-00942-z

关键词

Accumulative dose; Intracavitary brachytherapy; Interstitial brachytherapy; Deformable registration

资金

  1. Natural Science Foundation of Zhejiang Province [LSY19H180002]
  2. Zhejiang Province Key Research and Development Program [2019C03003]
  3. Medical Science and Technology Program of Zhejiang Province [2021PY039, 2021KY083]
  4. National Natural Science Foundation of China [12005190]

向作者/读者索取更多资源

The study investigated high-dose regions of two applicator approaches in brachytherapy, finding that 3D-printed ICBT showed better high-dose region consistency and predictability compared to freehand ISBT.
Background Image-guided adaptive brachytherapy shows the ability to deliver high doses to tumors while sparing normal tissues. However, interfraction dose delivery introduces uncertainties to high dose estimation, which relates to normal tissue toxicity. The purpose of this study was to investigate the high-dose regions of two applicator approaches in brachytherapy. Method For 32 cervical cancer patients, the CT images from each fraction were wrapped to a reference image, and the displacement vector field (DVF) was calculated with a hybrid intensity-based deformable registration algorithm. The fractional dose was then accumulated to calculate the position and the overlap of high dose (D2cc) during multiple fractions. Result The overall Dice similarity coefficient (DSC) of the deformation algorithm for the bladder and the rectum was (0.97 and 0.91). No significant difference was observed between the two applicators. However, the location of the intracavitary brachytherapy (ICBT) high-dose region was relatively concentrated. The overlap volume of bladder and rectum D2cc was 0.42 and 0.71, respectively, which was higher than that of interstitial brachytherapy (ISBT) (0.26 and 0.31). The cumulative dose was overestimated in ISBT cases when using the GEC-recommended method. The ratio of bladder and rectum D2cc to the GEC method was 0.99 and 1, respectively, which was higher than that of the ISBT method (0.96 and 0.94). Conclusion High-dose regions for brachytherapy based on different applicator types were different. The 3D-printed ICBT has better high-dose region consistency than freehand ISBT and hence is more predictable.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据