4.7 Article

Experimental study on flexural capacity of PVA fiber-reinforced recycled concrete slabs

期刊

出版社

SPRINGERNATURE
DOI: 10.1007/s43452-021-00314-3

关键词

Recycled concrete; Slab; PVA fiber; Failure mode; Flexural capacity

资金

  1. National Natural Science Foundation of China [51578001, 51878002, 52078001]
  2. Outstanding Youth Fund of Anhui Province [2008085J29]
  3. University Natural Science Research Project of Anhui Province [KJ2020A0234, KJ2020A0261]
  4. Key Research and Development Plan of Anhui Province [1704a0802131]
  5. University Synergy Innovation Program of Anhui Province [GXXT-2019-005]

向作者/读者索取更多资源

The study found that the PVA fiber content and replacement ratio of RCA have significant influences on the flexural performance of concrete slabs, affecting parameters such as ultimate moment, cracking moment, moment corresponding to crack width, and yield moment. By proposing applicable calculation formulas, the flexural capacities of PVA fiber-reinforced recycled concrete slabs can be conveniently predicted.
The flexural tests were conducted on 21 polyvinyl alcohol (PVA) fiber-reinforced recycled concrete slabs to investigate the influences of the reinforcement ratio, the PVA fiber content, the replacement ratio of recycled coarse aggregate (RCA) and the span-thickness ratio on the mechanical behaviors. The failure mode of the PVA fiber-reinforced recycled concrete slabs was the yielding of the longitudinal tensile reinforcement, slight crushing of concrete in the compression zone, and pulling out or breaking of PVA fiber at cracking position. The ultimate moment, cracking moment, moment corresponding to 0.2 mm-crack width and yield moment decreased as the replacement ratio of RCA or the span-thickness ratio increased while they increased as the reinforcement ratio or the PVA fiber content increased. Considering the impact of the PVA fiber content and the replacement ratio of RCA, the calculation formulas for conveniently predicting the flexural capacities of the PVA fiber-reinforced recycled concrete slabs were proposed. The formula prediction results were in good agreement with the test data.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据