4.7 Article

Thermodynamic analysis of auto-cascade refrigeration cycles, with and without ejector, for ultra low temperature freezing using a mixture of refrigerants R600a and R1150

期刊

APPLIED THERMAL ENGINEERING
卷 200, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2021.117598

关键词

Ultra-Low-Temperature

资金

  1. ERDF program [ITC-20181143]

向作者/读者索取更多资源

This study proposed two modifications of the auto-cascade system by including an ejector device to improve COP, using a mixture of ethylene and isobutane as alternative refrigerants. The results showed a potential improvement in COP of 12% when the ejector was used as an expansion device. The study concluded that the mixture of ethylene and isobutane is suitable for auto-cascade cycles and the ejector can be implemented to improve COP without adding excessive complexity and cost.
The temperatures required by ultra-low temperature applications, ranging from -50 degrees C to -100 degrees C, cannot be reached economically with single stage systems because of the limitation of the compression ratio. Different types of solutions such as cascade or two-stage systems could be implemented to achieve the desired working conditions. However, these systems are usually complex or too expensive. The solution might be found in the use of auto-cascade systems working with zeotropic mixtures. The present article proposes two modifications of the auto-cascade system by including an ejector device to improve the COP. The first modification includes the ejector as an expansion device at the outlet of the phase-separator, while the second includes the ejector as a precompression stage. A mixture of the hydrocarbons iso-butane (R600a) and ethylene (R1150) was used as an alternative to conventional refrigerants, which have a very high GWP. The study performed firstly assessed the sensitivity analysis of the free variables on the operating conditions of each cycle. The evaluated variables were the compressor pressure discharge, the mass fraction of the mixture and the phase separator temperature. In the case of the ejector enhanced cycles, the ejector efficiency and the motive pressure were additionally included. Then, the optimal operating conditions were found by means of an optimization process. The results showed a potential improvement in the COP of 12% for the case of the ejector as an expansion device, with an optimal mass fraction of 0.45 of ethylene. On the other hand, the ejector as a pre-compression stage did not show any improvement with regard to the reference case. The present study concludes that the mixture of ethylene and isobutane is a suitable combination for auto-cascade cycles and that the ejector can be implemented to improve the COP without adding excessive complexity and cost.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据