4.8 Article

Experimental study of the maximum power point characteristics of partially shaded photovoltaic strings

期刊

APPLIED ENERGY
卷 301, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2021.117436

关键词

Photovoltaic power generation; Maximum power point; Power variation; Partial shading; Maximum power point tracking; Photovoltaic string

资金

  1. Business Finland
  2. KAUTE Foundation

向作者/读者索取更多资源

This experimental study investigates the MPP characteristics of partially shaded strings of photovoltaic modules, eliminating the shortcomings of previous studies based on hypothetical shading patterns. The research shows that the global MPP voltage fluctuates widely, and by using the MPP closest to the nominal voltage as the operating point, significant reduction in energy losses can be achieved.
Under non-uniform operating conditions, like partial shading, electrical characteristics of photovoltaic generators can have multiple maximum power points (MPP) and the voltage of the global MPP can fluctuate over a broad voltage range. Since the highly variable global MPP voltage poses challenges for MPP tracking, it would be advantageous to keep the inverter operation point all the time at voltages close to the nominal MPP voltage. Earlier studies of MPP characteristics of photovoltaic generators have typically been simulation studies based on hypothetical shading patterns lacking knowledge of real operating conditions of photovoltaic cells. This article presents an experimental study of the MPP characteristics of partially shaded strings of 6 and 17 series-connected photovoltaic modules based on over 26000 measured current-voltage curves thus eliminating the shortcomings of earlier studies. Moreover, a scenario in which the MPP closest to the nominal MPP voltage is used the entire time as the operating point instead of the global MPP is studied for the first time. It was found that the global MPP of partially shaded photovoltaic strings varies over a broad voltage range and changes in its voltage and power can be extremely fast. The results show that the wide operating voltage range when the global MPP is followed can be significantly reduced by following the MPP closest to the nominal MPP voltage at a cost of negligible energy losses. The energy difference between the two MPPs was found to be insignificantly small from 0.03% to 0.35% of available energy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据